AC/DC Adapter
Detailed Product Description
5-30W series AC/DC Switching AC/DC Adapter with interchangeable plugs
1) Input Voltage Type: Universal Range
2) Attached Switchable Plugs: England, Europe, USA, Australia plugs
3) AC Input Voltage: 90~264 Vac, AC Input Frequency: 47~63 Hz
4) Operation Temperature: 0-40deg.
5) Protection: Short, Over Voltage, Over Current protection
6) Safety: CUL, TUV-PS/GS, CE, PSE/JQA, RoHs compliance
7) Weight: 180 grams
8) Dimension: 62 mm (L), 39 mm (W), 34 mm (H)
9) Packing: Inner White box 15.5*11.5*5.5cm, Carton: 48*46*30.5cm, 60pcs/carton
Output parameter:
DC output voltage | DC output current | Output voltage precision | Ripple&Noises | Regulation | Maximum output power | ||
Line | Load | ||||||
1 | 21-24V | 0-0.357A | 5% | 150mV | ±1% | ±5% | 7.5W |
2 | 16-20V | 0-0.47A | 5% | 150mV | ±1% | ±5% | 7.5W |
3 | 10-15V | 0-0.75A | 5% | 100mV | ±1% | ±5% | 7.5W |
4 | 9.4-9.9V | 0-0.8A | 5% | 100mV | ±1% | ±5% | 7.5W |
5 | 8.8-9.3V | 0-0.85A | 5% | 80mV | ±1% | ±5% | 7.5W |
6 | 8.2-8.7V | 0-0.91A | 5% | 80mV | ±1% | ±5% | 7.5W |
7 | 7.6-8.1V | 0-0.98A | 5% | 70mV | ±1% | ±5% | 7.5W |
8 | 7.0-7.5V | 0-1.07A | 5% | 70mV | ±1% | ±5% | 7.5W |
9 | 6.4-6.9V | 0-1.17A | 5% | 60mV | ±1% | ±5% | 7.5W |
10 | 5.8-6.3V | 0-1.29A | 5% | 60mV | ±1% | ±5% | 7.5W |
11 | 5.2-5.7V | 0-1.44A | 5% | 60mV | ±1% | ±5% | 7.5W |
12 | 4.6-5.1V | 0-1.5A | 5% | 50mV | ±1% | ±5% | 7.5W |
13 | 4.0-4.5V | 0-1.5A | 5% | 50mV | ±1% | ±5% | 6.75W |
14 | 3.4-3.9V | 0-2.0A | 5% | 50mV | ±1% | ±5% | 6.8W |
15 | 2.8-3.3V | 0-2.0A | 5% | 50mV | ±1% | ±5% | 6.6W |
DC output voltage | DC output current | Output voltage precision | Ripple&Noises | Regulation | Maximum output power | ||
Line | Load | ||||||
1 | 31.5-48.0V | 0.02-0.95A | 5% | 150mV | ±1% | ±5% | 30W |
2 | 30.5-31.0V | 0.025-0.98A | 5% | 150mV | ±1% | ±5% | 30W |
3 | 22.1-30.0V | 0.03-1.36A | 5% | 100mV | ±1% | ±5% | 30W |
4 | 18.2-22.0V | 0.035-1.67A | 5% | 100mV | ±1% | ±5% | 30W |
5 | 12.0-17.9V | 0.04-2.5A | 5% | 100mV | ±1% | ±5% | 30W |
6 | 11.1-11.9V | 0.04-2.25A | 5% | 100mV | ±1% | ±5% | 25W |
7 | 9.1-10.0V | 0.055-2.75A | 5% | 100mV | ±1% | ±5% | 25W |
8 | 8.1-9.0V | 0.06-3.57A | 5% | 100mV | ±1% | ±5% | 25W |
9 | 7.0-8.0V | 0.07-4.1A | 5% | 100mV | ±1% | ±5% | 25W |
10 | 6.0-6.9V | 0.08-4.0A | 5% | 100mV | ±1% | ±5% | 25W |
11 | 4.1-6.0V | 0.08-4.0A | 5% | 100mV | ±1% | ±5% | 24W |
12 | 3.0-4.0V | 0.1-4.0A | 5% | 100mV | ±1% | ±5% | 16W |
Electrical Specifications: | Symbol | Min | Typ | Max | Units | Comment | ||
Input | ||||||||
Voltage | VIN | 90 | 120/240 | 264 | Vac | 2 Wire no Protective Ground | ||
Frequency | FLINE | 47 | 50/60 | 63 | Hz | |||
No-load Input Power(230VAC) | 0.3 | W | ||||||
Efficiency | η | 75 | % | |||||
Inrush Current(240VAC) | I | 60 | A | Cold 25 | ||||
Environmental | ||||||||
Operating Temperature | T | 0 | / | 40 | Free convection,Seal level | |||
Non-operating | T | -20 | / | 80 | Free convection,Seal level | |||
Operating humidity | T | 10 | / | 90 | %RH | Non condensing | ||
Non-operating humidity | T | 10 | / | 90 | %RH | Non condensing |