Ideal modified bitumen equipment; Heating; Agitate the bitumen with SBS, SIS, SBR, CRM, and so on; Mixer; Intellectual control
Rubber modified bitumen heating tank
No | Designation | Dimension(mm) | Standard/Model | Quantity |
1 | Frame | 8490×2430×2595 |
| 1 |
2 | Tank body | 6010×2130×2180 | 20m3 | 1 |
3 | Insulation /outside insulation cladding | Rock wool 50/stainless steel 0.8 |
| 1 |
4 | Flue tube | 460×325×219 |
| 1 |
5 | Refractory mortar | 1040 mm×25 mm |
| 1 |
6 | Gasoil burner |
| G20 | 1 |
7 | Scavenger coil | 50×10Piece×5.5m |
| 1 |
8 | Helical mixer shaft | 108×160(blade radius) |
| 2 sets |
9 | Cardan |
|
| 2 sets |
10 | Shaft block |
|
| 4 sets |
11 | Helical mixer reducer |
| Transmission ratio8.27 /15kw | 1 |
12 | Helical mixer reducer motor |
| Rotate speed1460/15kw | 1 |
13 | Bitumen pump | Rate of flow 50m3/h | QS224A | 1 |
14 | Bitumen pump reducer |
| 160L-4 | 1 |
15 | Bitumen pump reducer motor | CRW37-4.9-Y-15-B6-0 | 15KW | 1 |
16 | Bitumen pipe adjusting valve | PN.1.0mpa/-40~+300°C | DN100 | 3 sets |
17 | Hot oil disconnecting valve(manual drive) |
| DN40 | 2 sets |
18 | Turbine worm adjusting valve(manual drive) |
| DN100 | 2 sets |
19 | Floating ball level indicator |
|
| 1 |
20 | Floating ball limit switch |
|
| 1 |
21 | Temperature visual meter |
|
| 1 |
22 | Sensor | Normal temperature-200°C-420°C | WZP-230 | 1 |
23 | Diesel oil tank/diesel oil filter |
|
| 1 |
24 | Compound manhole |
|
| 2 |
25 | Ladder |
|
| 1 |
26 | Tank body supporting leg |
|
| 2 |
27 | Drain hole |
| DN50 | 1 |
28 | Electrical control box |
|
| 1 |
29 | Loading conveyer |
| 4-6t/h | 1 |
Rubber Modified Bitumen Heating Tank