Welcome to ECBAY
AM1(CM1) Series Moulded Case Circuit Breaker
AM1(CM1) Series Moulded Case Circuit Breaker

AM1 Moulded Case Circuit Breaker 1.6A-1250A 2.Working voltage: up to 800V 3.Certification:IEC60947-2 4.Good quality

AM1 Moulded Case Circuit Breaker (MCCB)

1. ApplicationAM1 series moulded case circuit breaker is one of products developed and manufactured byadopting international advanced technology. It is supplied with rated insulating voltage 800Vand used for circuit of A.C. 50Hz, rated operating voltage AC 400V (or below), rated operatingcurrent up to 800A for infrequent changing over and starting of the motors.The products con-forms to IEC60947-2 standard.2. Main Technical Specification(table1)

TypeRatedcurrent (A)Polenum-berRatedinsui-atingvolt-age(V)Ratedoperat-ingvolt-age(V)Arcing-overdistance(mm)Ultimateshortcircuitbreakingcapacity(KA)Serviesshortcircuitbreakingcapacity(KA)Operationperform-anceUtiliza-tioncat-egory
LoadUnload
AM1-63L(6),1016,2025 ,3240,50633, 4500V400V0251815008500A
AM1-63M05035
AM1-100L(10),1620,2532,4050,6380,100800V0(≤50)3522
AM1-100M0(≤50)5035
AM1-100H0(≤50)855010007000
AM1-225L100,125160,180200,225≤503522
AM1-225M≤505035
AM1-225H≤50855010004000
AM1-400L225,250315,350400≤505035
AM1-400M≤1006542
AM1-630L400,500630≤1005035
AM1-630M≤1006542
AM1-630H≤10010065
AM1-800M630,7008003≤1007550
AM1-800H≤10010065
AM1-1250M1000,1250≤10010065
AM1-1250H≤1001255

Note: 6A no thermal protection The N-pole of four-poles breaker is sifed at the right side of the product has four types: Type A: No current trip-lease on N pole which making all the time, not closing and opening with the otherthree poles. Type B: No current trip-release on N pole which closing and opening with the other poles. Type C: With current trip-release which closing and opening with the other three poles. Type D: With current frip-release which making all the time not closing and opening with the other threepoles.3. Protection CharacteristicThe thermodynamic release of a circuit breaker provides the feature of inverse time-delay,while the magnetic release is the instantaneous operation as shown on table 2(distribution cir-cuit breaker) and table 3 (motor protection circuit breaker).Table2

Rated current ofrelease (A)Thermodynamic release( ambient temp )Operationalcurrent ofmagneticrelease (A)
1.05In(cold state)Inoperative time(h)1.30In(heat state)Operative time(h)
10≤In≤63≥1< 110In±20%
225≤In≤630≥2< 2
100≤In≤800≥2< 25In±20%

Table3

Rated current ofrelease (A)Thermodynamic release( ambient temp )Operationalcurrent ofmagneticrelease (A)
1.0In(cold state)Inoperative time(h)1.20In(heat state)Operative time (h)1.50In(heat state)Operative time (h)7.2In(cold state)Operative time(h)
10≤In≤225≥2<2≤4min≤8min4s< Tp ≤10s6s< Tp ≤20s12In±20%
225≤In≤630

 

We can offer you good quality with competitive price.

Sincerely hope to cooperate with you.