FPM8000 Portable patient monitor Patient monitor medical monitor surgical monitor medical equipment
Product detail
15'' color super light LCD display with maximum 9 waveforms;
Display resolution 1024768 pixels;
7-lead waveforms rolling display synchronized;
Monitoring parameters including ECG/RESP, NIBP, SPO2, PULSE RATE and DUAL-TEMP;
Maximum 96-hour graphic and tabular trends of all parameters;
Arrhythmia analysis, multi-lead S-T segment and pacemaker detection;
ECG waveforms cascade;
5-min ECG real time waveform storage and review;
50-set vital sign data recall;
Net working capacity;
Operation Environment
Power Requirements:AC 100-250V ,50/ 60Hz
Temperature:1030
Humidity:≤70%
Application Scope
Adult, child and neonatal
ECG
Lead type:5-lead or 3-lead selectable
Input:5-lead: RA;LA;RL;LL;V or R;L;N;F;C
3-lead: RA;LA;LL or R;L;F
Lead Selection:I;II;III;avL;avF;Vx;CAL
Gain selection: 0.25;0.5;×1;×2;Auto
Sweep speed:12.5 mm/s,25mm/s.50mm/s
Heart Rate range: Adult:15-300bpm
Pediatric/Neonatal:15-350bpm
Accuracy:±1bpm or ±1%, whichever is greater
Resolution:1pm
CMRR:Diagnostic mode: >90dB
Monitoring mode:>105dB
Operating mode:>105dB
Protection:withstand 4000VAC/50Hz voltage in isolation, against electrosurgical
Calibration Signal:1mV±5%
Operation Modes:Diagnostic, Monitor, Surgery
Bandwidth:0.05-100Hz
Alarm Range: Adult: 15-300bpm
Pediatric/Neonatal: 15-350bpm
S-T detection:YES
Measurement range: -2.0mV~2.0mV
Alarm range: -2.0mV~2.0mV
Arrhythmia analysis:YES
Pacemaking Analysis:YES
Respiration
Method:RA-LL impedance
Measurement range: Adult:6-120rpm
Pediatric/Neonatal:6-150rpm
Resolution:1pm
Accuracy:±2% or ±2rpm,whichever is greater
Alarm Range:Adult: 6-120rpm
Pediatric/Neonatal: 6-150rpm
Apnea alarm:YES
Apnea delay: 10-40 seconds
NIBP
Method:Automatic Oscillometric
Operation modes:Manual /Automatic/Continuous
Measurement unit: mmHg /kPa selectable
Measurement types: Systolic, Diastolic, Mean pressure
Measurement range: Adult: 0-250mmHg
Pediatric: 0-200mmHg
Neonatal: 0-180mmHg
Over-pressure protection: YES
Resolution:1mmHg
Accuracy:Mean error and standard deviation per ANSI/AAMI SP-10
Alarm:Systolic, Diastolic, Mean
SpO2
Measurement range: 0-100%
Resolution:1%
Accuracy:+2 digit (70~100%);
0~69%unspecified
Alarm range:1~100%
Pulse rate:Range:20~250bpm
Resolution: 1bpm
Accuracy: ±1bpm
Alarm range: 20~250bpm
Temperature
Measurement range: 0~50.0
Resolution:0.1
Accuracy :±0.1
Alarm range:0~50.0
Channel:1channel/2channel(option)
FPM8000 Portable patient monitor --(CE Approved)