signal multi core control cable pvc insulated 1. multi core control cable 2. copper conductor 3. rated voltage: 450/750v
Signal multi core control cable pvc insulated
Control Cable, Signal control cable , Measuring system cable
1. Standard
The control cable can be produced according to the standard GB9330-1988. Our factory can also produce cables in accordance with other standards.
2. Detailed types
Type | Name | Section Area(mm2) | No. of Core |
KVV | Copper core, PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16 19 24 27 30 37 |
4.0 6.0 | 2-8 10 12 14 | ||
KVVP | Copper core, PVC Insulated and Sheathed ,Braided and Screened Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16 19 24 27 30 37 |
4.0 6.0 | 2-8 10 12 14 | ||
KVVP2 | Copper core, PVC Insulated and Sheathed, Copper-tape Screened Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16 19 24 27 30 37 |
4.0 6.0 | 2-8 10 12 14 | ||
KVVP22 | Copper core, PVC Insulated and Sheathed, Braided and Screened Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16 19 24 27 30 37 |
4.0 6.0 | 2-8 10 12 14 | ||
KVVP2-22 | Copper core, PVC Insulated and Sheathed, Copper-tape Screened, Steel-tape armored Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16 19 24 27 30 37 |
4.0 6.0 | 2-8 10 12 14 | ||
KVV22 | Copper core, PVC Insulated and Sheathed, Steel-tape armored Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16 19 24 27 30 37 |
4.0 6.0 | 2-8 10 12 14 | ||
KVVR | Copper core, PVC Insulated and Sheathed, Flexible Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16 19 24 27 30 37 |
4.0 6.0 | 2-8 10 12 14 | ||
KVVRP | Copper core, PVC Insulated and Sheathed, Braided and Screened Flexible Control Cable | 0.75 1.0 1.5 2.5 | 2-8 10 12 14 16 19 24 27 30 37 |
4.0 6.0 | 2-8 10 12 14 |
We also produce flame-retardant control cable, XLPE insulated control cable, XLPE insulated flame-retardant control cable, low smoke halogen free flame-retardant control cable etc.
3. Scope of Application
Control cable is suitable for the wiring of electrical controlling equipments and instrument, monitoring and controlling return circuit, electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.
4. Service Condition
(1) The long-time working temperature of conductor of PVC insulated cable is 70oC,
XLPE insulated cable 90oC
(2) The temperature for laying the cables can not be lower than 0 oC. Permissible bending radius(r): unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D
5. Characteristic
Control cable has low capacitance and inductance, have excellent ability of screen and anti-jamming, so the anti-blast ability is better than the common cable for computer and control cable.
signal multi core control cable pvc insulated