1.silent diesel generator set 2.750KVA 3.cummins engine,stamford Alternator
1.silent diesel generator set2.750KVA3.cummins engine,stamford Alternator
Model | Prime Power | Standby Power | ||||||
VC600E | 600KW/750KVA | 660KW/825KVA
| ||||||
Power Output at Different Voltage | ||||||||
Voltage(V) | Frequency(Hz) | Phases | PF(cos) | Standby Current(A) | Prime Current(A) | Standby Power(KW/KVA) | Prime Power(KW/KVA) | |
440/254 | 50 | 3 | 0.8 | 1083 | 984 | 660/825 | 600/750 | |
400/230 | 50 | 3 | 0.8 | 1191 | 1083 | 660/825 | 600/750 | |
380/220 | 50 | 3 | 0.8 | 1253 | 1140 | 660/825 | 600/750 |
Alternator Data | |
In compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards | |
Manufacturer / Type: | STAMFORD/ LVI6B |
Number of Phase: | 3 |
Connecting Method: | 3 Phase and 4 Wires, “Y” type connecting |
Number of Bearing: | 1 |
Power Factor: | 0.8 |
Protection Grade: | IP23 |
Altitude Requirement: | ≤1000m |
Exciter Type: | Brushless, Self-exciting |
Insulation Class/Temperature Rise: | H/H |
Telephone Influence Factor (TIF): | 50 |
THF: | 2% |
Steady State Voltage Regulation: | ≤±1% |
Alternator Capacity: | 750KVA |
Alternator Efficiencies: | 93.30% |
Air Cooling Flow: | 130.8m3/min |
Specification can be changed without notice | |
Engine Data | |
Manufacturer / Model: | Cummins(CCEC) /KTA38-G2 |
Air Intake System: | 4 Cycle,Turbocharger, Air-to-Water Aftercooled |
Fuel System: | PT Fuel Systerm |
No. of Cylinder: | 12 - In V |
Displacement: | 37.8L |
Bore×Stroke: | 159×159(mm) |
Compression Ratio: | 14.5 |
Rated RPM: | 1500rpm |
Max. Standby Power at Rated RPM: | 731KW |
Governor Type: | High-precision Electric Speed Governor |
Steady State Frequency Regulation: | ±0.5% |
RPM of Piston: | 7.6m/s |