Welcome to ECBAY
60KW DEUTZ Diesel Generator
60KW DEUTZ Diesel Generator

Diesel Generator 1) Type:60KW 2) Cetificate:CE 2) With Automatic Transfer System 3) Place of origin:Weifang, Shandong,China

 60KW  diesel generator

1,Model: TFW2-60                                  

Power Output (Prime): 75KVA/60KW

Power Factor:  COSΦ=0.8(Lagging)

Max. Current Output: 108A

Voltage Output: 230/400V

Ventilation Capacity: 4.9m3/s

24V Electric Starter

Weight: 1000kg(Net) 

L*W*H(mm):  2000×900×1380

2,Diesel Engine:

Brand: DEUTZ

Model: 226B-6D

No. of Cylinders: 6

Type of Cylinder: Vertical In-line

Bore/stroke: 105/120

Starting mothod: electric starting

Rotation Speed: 1500RPM

Fuel Consumption: 196g/kw.h

Oil consumption rate: 1.36g/kw.h  

 Lubricating method:Forced lubricating  

Air Intake System: Turbocharged

3,Alternator:

Brand: Marathon

Model: TWF2--60

Insulation Class: H

Type of Excitation: Brushless self-excitation

Protection Class:  IP23

Vol. Control Method: AVR(Automatic Voltage Regulation)

Voltage Regulation Rate:  ±1%

Vol. Harmonic Wave Distorted: <4%

 Feasures(silent generator)

1)      Rated output: 60KW(75KVA)

2)      230V/400V or 120/240V, less than 224g/kw.h for fuel consumption,50/60Hz,0.8 lagging for power frequency,1500/1800rpm,3-phase 4-wire  or 1-phase 3-wire

3)      Engine model: 226B-6D

4)      6 cylinders,water-cooled

5)      Alternator model:Marathon,Stamford

Alternator citation way: brush or brushless

6)      Key start or auto start

7)      8hrs operating base tank

8)      Frequency:3%

a)       Frequency at stable state: less than 0.5%

b)      Frequency deviation at instantaneous state: less than 10%

c)      Frequency return time:less than 3s

9)      Voltage deviation at stable state: less than 1%

a)       Voltage deviation at instantaneous state: less than 20%

b)      Voltage return time: less than 4s

c)      Voltage modulation: less than 0.3%

10)   Open ,soundproof or waterproof or automation genset is optional

11)   Control system:

a)       Automatic alarm system: the unit has the acoustic-optics device(AOD) alarm system and arrestor for any situation as the start defeat, the water is over temperature,the oil polls down,over speed,over load and over current

b)      Operation display

i)                    Unit voltage,tri-phase load current and frequency display

ii)                   Water temperature,oill pressure display

iii)                 Fuel level,fuel temperature display

iv)                 Audible and visual alarm lamp and buzzer

60KW DEUTZ Diesel Generator

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.