Detailed Product Description


The gas meter's specifications:
 

I.                    General

Model RE-J1.6/2.5 household diaphragm type fuel gas meter (also called gas meter), which the case is made of aluminium alloy by die casting. And the plastic part is processed and formed by high strength engineering plastic. This product still can reach each requirement under long-term working owing to the high quality material and reasonable structural design. The technical criteria of this series gas meter comply with the requirement provision in <GB/T 696801997 Diaphragm Type Gas Meter). It is a perfect measuring instrument in fuel gas industry.

II.                 Application

Model RE-J1.6/2.5 gas meter is suitable for measuring of natural gas liquefied petroleum gas, artificial gas, air and other noncorrosive gas.

III.               Characteristics

Diaphragm type structure, advanced process, big character wheel , counting device, accurate measuring.

IV.              Installation.

1.      Please read the Operation Manual carefully before installing. It should be installed by qualified professional department that complies with the requirement of GB50028-93 city gas design specification.

2.      Selecting the left inlet or the right inlet of gas meter according to the pipeline position. Install the junction and connected with the pipeline of the owner according to the airflow direction.

3.      During the installation, storage and transportation, it is forbidden to break, touch, convert and shake. And do not open the surface at will to avoid entering water and sundries.

4.      It should fill with 10kPa air (or other effective methods) to conduct air tightness examination after finishing installing, it shouldnt put in use until ensuring.

V.                 Points for attention

1.      It is forbidden to use open fire, to leak inflammability and explosive and poisonous gas.

2.      It is strictly forbidden to disassemble personally;

3.      The air inside the pipeline and meter should be emptied before using.

4.      When found the leakage, the front valve of the meter should be closed immediately, and open door and window to exchange the air. And inform the related department to repair.

VI.              Main Technical Parameter

Item

Unit

Parameter

RE-J1.6 Model

RE-J2.5 Model

Qn

M3/h

1.6

2.5

Qmax

M3/h

2.5

4.0

Qmin

M3/h

0.016

0.025

Pmax

kPa

10

Basic error

%

Qmin<=Q<0.1Qmax+-3  0.1Qmin<=Q<=Qmax+-1.5

Pressure loss

Pa

Qmax<=200

Air tightness


The gas meter does not leak when input maximum working pressure of 1.5 times under normal working condition.

Long-term running performance


It also can reach the above-mentioned indexes after running 2000 hours under the maximum flow capacity.

Overall dimension

mm

168*135*220

175*135*228

Screw thread for junction of meter


M30*2

M30*2

Center distance for junction of meter

mm

130

130

Gas meter

kg

1.7

1.8