FM-6000 Multi-parameter Hand-held patient monitor
FM-6000 Multi-parameter Hand-held patient monitor

Multi-parameter patient monitor system FM-6000 1.Samll, easy to carry. 2.Fashionable shape.

Multi-parameter patient monitor system FM-6000

The features of patient monitor (FM-6000) as follows;

1) Standard configuration: 5 lead ECG, Respiration, Temperature, Heart Rate/ Pulse Rate, SpO2, NIBP.

2)12.1 inch real-color TFT LCD display.

3) Built-in Rechargeable Battery for patient transport.

4)Network function for monitors to connect to the central station.

5) Trend data display for 256 hours.

6)Manual printing and alarm trigger printing functions availbale.

7) High resistance to interference of high-frequency electrotome and defibrillator.

Operating condition

Temperature range: Operating 0-45°C

Saving and transporting -20-60°C

Dampness range: Operating <=85%

Saving and transporting <=95%

Altitude range: Operating -500-4,600m

Saving and transporting -500-13,100m

Electrical sp

Specification of screen

True color, 12.1”TFT type LCD, distinguish rate 800×600

Signal interface

Interface of exterior display: Standard VGA

Exterior communication interface: RS422/RS485

Exterior printer interface: Standard combines

Record apparatus

Record width: 50mm

Paper feed speed: 25mm/s

Recording waveform: 3 ways

Record type: continuously real time record

Manually one time record

Time striking record

Alarm striking record

Trend saving

6 hours/1 second—128 hours/1 minute

Specification of ECG

Lead mode: 12 leads (R, L, F, N, C1,C2,C3,C4,C5,C6)

Method of Lead: Ⅰ,,,aVR,aVL,aVF,V1,V2,V3,V4,V5,V6 ⅡⅢ

Waveform of Lead: 12 ways

Gain: ×0.5 ,×1,×2,×4

Mode: diagnoses mode, monitoring mode, and operating mode

Input resistance: >5 MΩ

Coenelasma suppression ratio: >90dB

Polarization voltage range of electrode: ±300mV

Drain current: <30μA

Resuming time of base line: after defibrillation<3s

Range of ECG signal: ±10 mV (peak value)

Frequency response: Diagnoses mode 0.05-100Hz

Monitoring mode 0.5-40Hz

Operation mode 1-20Hz

Heart rate

Measuring range: 10-300 bmp

Measuring accuracy: ±1%

Definition: 1bpm

Sensitivity ratio: >0.2mV (peak value)

Respiration specification

Method: RA-LA resistance

Input the resistance: >2.5 MΩ

Bandwidth: 0.1-2Hz

Respiration rate: 0-120 rpm

Measuring range: 0-120 rpm

Definition: 1 rpm

Sensitivity ratio: ±2 rpm

Specification of NIBP

Measuring method: method of shocking automatically

Operating mode: manual, periodic and continuous

Partition of periodic measure: 5,10,45,60 minutes

Continuous mode: 5 minutes

Range of pulse rate: 40-240 bpm

Measuring range:

Adult: Systolic pressure 25-255 mmHg

Diastolic pressure 10-220 mmHg

Mean pressure 15-235 mmHg

Child: Systolic pressure 20-135 mmHg

Diastolic pressure 10-110 mmHg

Mean pressure 15-125 mmHg

Definition: 1 mmHg

Sensitivity ratio: Max average error ±5 mmHg

Max standard error 8 mmHg

Overvoltage protection: Adult 290 mmHg

Child 145 mmHg

Specification of SPO2

Measuring range: 0-100%

Definition: 1%

Sensitivity ratio: 70-100% ±2%

40-69% ±3%

0-39% not explain

Refresh time: About a second

Alarm delay: 10 seconds

Pulse rate: Measuring range 0-254 bmp

Definition 1bmp

Sensitivity ratio ±2 bpm

Alarm delay 10 seconds

Specification of TEMP

Measuring range: 0°C-50°C

Definition 0.1°C

Sensitivity ratio: ±0.2°C

Refresh time: About a second

Average time constant: <10s