Multi-parameter patient monitor system FM-6000 1.Samll, easy to carry. 2.Fashionable shape.
Multi-parameter patient monitor system FM-6000
The features of patient monitor (FM-6000) as follows;
1) Standard configuration: 5 lead ECG, Respiration, Temperature, Heart Rate/ Pulse Rate, SpO2, NIBP.
2)12.1 inch real-color TFT LCD display.
3) Built-in Rechargeable Battery for patient transport.
4)Network function for monitors to connect to the central station.
5) Trend data display for 256 hours.
6)Manual printing and alarm trigger printing functions availbale.
7) High resistance to interference of high-frequency electrotome and defibrillator.
Operating condition
Temperature range: Operating 0-45°C
Saving and transporting -20-60°C
Dampness range: Operating <=85%
Saving and transporting <=95%
Altitude range: Operating -500-4,600m
Saving and transporting -500-13,100m
Electrical sp
Specification of screen
True color, 12.1”TFT type LCD, distinguish rate 800×600
Signal interface
Interface of exterior display: Standard VGA
Exterior communication interface: RS422/RS485
Exterior printer interface: Standard combines
Record apparatus
Record width: 50mm
Paper feed speed: 25mm/s
Recording waveform: 3 ways
Record type: continuously real time record
Manually one time record
Time striking record
Alarm striking record
Trend saving
6 hours/1 second—128 hours/1 minute
Specification of ECG
Lead mode: 12 leads (R, L, F, N, C1,C2,C3,C4,C5,C6)
Method of Lead: Ⅰ,,,aVR,aVL,aVF,V1,V2,V3,V4,V5,V6 ⅡⅢ
Waveform of Lead: 12 ways
Gain: ×0.5 ,×1,×2,×4
Mode: diagnoses mode, monitoring mode, and operating mode
Input resistance: >5 MΩ
Coenelasma suppression ratio: >90dB
Polarization voltage range of electrode: ±300mV
Drain current: <30μA
Resuming time of base line: after defibrillation<3s
Range of ECG signal: ±10 mV (peak value)
Frequency response: Diagnoses mode 0.05-100Hz
Monitoring mode 0.5-40Hz
Operation mode 1-20Hz
Heart rate
Measuring range: 10-300 bmp
Measuring accuracy: ±1%
Definition: 1bpm
Sensitivity ratio: >0.2mV (peak value)
Respiration specification
Method: RA-LA resistance
Input the resistance: >2.5 MΩ
Bandwidth: 0.1-2Hz
Respiration rate: 0-120 rpm
Measuring range: 0-120 rpm
Definition: 1 rpm
Sensitivity ratio: ±2 rpm
Specification of NIBP
Measuring method: method of shocking automatically
Operating mode: manual, periodic and continuous
Partition of periodic measure: 5,10,45,60 minutes
Continuous mode: 5 minutes
Range of pulse rate: 40-240 bpm
Measuring range:
Adult: Systolic pressure 25-255 mmHg
Diastolic pressure 10-220 mmHg
Mean pressure 15-235 mmHg
Child: Systolic pressure 20-135 mmHg
Diastolic pressure 10-110 mmHg
Mean pressure 15-125 mmHg
Definition: 1 mmHg
Sensitivity ratio: Max average error ±5 mmHg
Max standard error 8 mmHg
Overvoltage protection: Adult 290 mmHg
Child 145 mmHg
Specification of SPO2
Measuring range: 0-100%
Definition: 1%
Sensitivity ratio: 70-100% ±2%
40-69% ±3%
0-39% not explain
Refresh time: About a second
Alarm delay: 10 seconds
Pulse rate: Measuring range 0-254 bmp
Definition 1bmp
Sensitivity ratio ±2 bpm
Alarm delay 10 seconds
Specification of TEMP
Measuring range: 0°C-50°C
Definition 0.1°C
Sensitivity ratio: ±0.2°C
Refresh time: About a second
Average time constant: <10s
FM-6000 Multi-parameter Hand-held patient monitor