This sleeving possesses reliable heat resistance, good qualities of dielectric, excellent softness and elasticity.

2741 Fiberglass sleeving coated withe Polyurethane

(In accordance with Q/CGJD05-2008,IEC60684-3-409)

Fiberglass sleeving coated with polyurethane is manufactured with non-alkali fiberglass braided sleeving and coated it with acryl ate latex and polyurethane and then heated it to form F grade insulating sleeving. It possesses reliable heat resistance, good qualities of dielectric, excellent softness and elasticity. It can be used for wiring insulation and mechanic protection for F grade electrical machinery electric appliances.

Length: 1000(+20,-10) mm (continuous length may be negotiated)

Requirements of Property:

Bending after heating: No visible cracking or detachment of coating,and the colour shall be cleary recognizable.(use a test temperature of 180±3K.)

Bending at low temperature: No sivible cracking or detachment of coating.

( use a test temperature of -15±3K.)

Hydrolysis of coating: No running of the coating.No adherence between sleeving and paper or between the pieces of sleeving.No sign of discoloration of the paper

Flam propagation:60seconds max, The indicator flag on any of the three test specimens shall

not be burned,burned awayor charred,nor shall flaming or glowing particles or flaming drops ignite the cotton.

Temperature index: 155oC

 

Bore diameter(mm)

Wall thickness(mm)

Nominal

Tolerance

Nominal

Tolerance

0.5

±0.15

0.50

±0.15

1, 1.5, 2, 2.5

±0.20

0.50

± 0.15

3, 4, 5, 6

±0.25

8, 9, 10 ,12

±0.30

0.70

± 0.20

14,16,18,20

±0.50

0.70

±0.30

25

±0.60

1.0

±0.50

30

±0.60

1.5

±0.50

Requirement for breakdown voltage( kv min)

Remarks

At room temperture

At elevated temperature

At damp heat

Test medthod:

straight mandrel with 100mm electrode

Lowest value

Central value

Lowest value

Central value

Lowest

value

Central value

5

6

3.5

4

2.5

3.5

The test at elevated temperature shall be carried out at 155± 3K