1.1KW~6KW solar inverters for home use 2.Pure sine wave 3.Auto OLP,OCP,OTP,SCP 4.Self recover function
1000W 2000W 3000W 4000W 5000W 6000W solar inverters for home use
Outstanding features: for home use
Durable construction for long life under extreme environmental conditions 70 amp automatic three-stage battery charger (bulk, absorption, and float) Low idle current (less than 1 watt) conserves energy when no loads are present Built-in starting control circuits for two- and three-wire generator starting systems
MODEL IR series | LW INVERTER | |||||||
1000W 12V | 1000W 24V | 2000W 12V | 2000W 24V | 3000W 24V | 4000W 48V | 5000W 48V | 6000W 48V | |
Line Mode Specifications: | ||||||||
Input Voltage Waveform | Sinusoidal (utility or generator) | |||||||
Nominal Input Voltage | 230Vac(120VAC selectable) | |||||||
Low Line Disconnect | 184Vac±4% | |||||||
Low Line Re-connect | 194Vac ±4% | |||||||
High Line Disconnect | 265Vac±4% | |||||||
High Line Re-connect | 255Vac±4% | |||||||
Max AC Input Voltage | 270Vrms | |||||||
Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | |||||||
Low Line Frequency Re-connect | 58+0.3Hz for 60Hz;48+0.3Hz for 50Hz; | |||||||
Low Line Frequency Disconnect | 57+0.3Hz for 60Hz;47+0.3Hz for 50Hz; | |||||||
High Line Frequency Re-connect | 64+0.3Hz for 60Hz;54+0.3Hz for 50Hz; | |||||||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz;55+0.3Hz for 50Hz; | |||||||
Output Voltage Waveform | As same as Input Waveform | |||||||
Over-Load Protection(SMPSload) | Circuit breaker | |||||||
Output Short Circuit Protection | Circuit breaker | |||||||
Efficiency (Line Mode) | >95% | |||||||
Transfer Switch Rating | 30A | |||||||
Transfer Time (Ac to Dc) | 10ms (typical) | |||||||
Transfer Time (Dc to Ac) | 10ms (typical) | |||||||
Pass through without Battery | Yes | |||||||
Max Bypass Overload Current | 30A | |||||||
Invert Mode Specifications: | ||||||||
Output Voltage Waveform | Sine wave | |||||||
Power Factor | 0~1.0 | |||||||
Nominal Output Voltage (V) | 230Vac | |||||||
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz | |||||||
Auto tracking Main Frequency(Hz) | Yes (Following Main first connection)50Hz @48-54Hz ;60Hz @58-64Hz | |||||||
Output Voltage Regulation | ±10% rms | |||||||
Nominal Efficiency | >80% | |||||||
Surge rating (10s) | 3000VA | 6000VA | 9000VA | 12000VA | 15000 VA | 18000VA | ||
Capable of starting electric motor | 1 HP | 1 HP | 2 HP | 3 HP | ||||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||||||
Inverter overload Breaker Size | 30A | 30A | 30A | 35A | 50A | |||
Nominal DC Input Voltage | 12V | 24V | 12V | 24V | 24V | 48V | 48V | |
Min DC start voltage | 10V/20V/40V | |||||||
Power saver | Load ≤25W (Enabled on “P/S auto” setting of Remote control) | |||||||
Charge Mode Specifications: | ||||||||
Nominal Input Voltage | 230Vac | |||||||
Input Voltage Range | 196~243Vac | |||||||
Nominal Output Voltage | According to the battery type | |||||||
Nominal Charge Current | 35A | 35A | 65A | 35A | 45A | 35A | 40A | 50A |
Charge Current Regulation | ± 5Adc | |||||||
Battery initial voltage | 0 –15.7 Vdc (can operate with 0V battery) | |||||||
Charger Short Circuit Protection | Circuit breaker | |||||||
Over Charge Protection | Bat. V ≥ 15.7Vdc/31.4Vdc,beeps 0.5s every 1s & fault after 60s | |||||||
General Specifications | ||||||||
Safety Certification | CE(EN62040-1) | |||||||
EMC Classification | EN62040-2,C2 | |||||||
Operating Temperature Range | 0°C to 40°C | |||||||
Storage temperature | 15°C below zero to 60°C | |||||||
Operation humidity | 5% to 95% | |||||||
Audible Noise | 60dB max | |||||||
Cooling | Forced air, variable speed fan |
1000W 2000W 3000W 4000W 5000W 6000W solar inverters for home use