New with V 1.1 Upgrade! Zoom on trend provide unprecedented ability to view analyze TrendCapture data; see detail at X5 magnification. New with V 1.1 Upgrade! Simplified Record screen when setting up recording New with V 1.1 Upgrade! Logging function with expanded memory for unattended monitoring of signals over time. Using on-board TrendCapture users can graphically review logged readings without needing a PC. Store up to 15,000 recorded events. Large 50,000 count, VGA display with white backlight. Multiple sets of measurement information can simultaneously be displayed at the same time. Logging function with TrendCapture is an essential tool for documenting the performance of your designs, processes or systems, or unattended monitoring while you work on other projects. It plots measurements as a single line to help detect signal anomalies over time. Using on-board TrendCapture, you can graphically view logged readings without a PC. (Software and interface cable optional). Log multiple sessions or log data continuously for over 200 hours. i-info button. On board help screens for measurement functions. Unsure about a function? Go to that function and Press the “i” button. Now, name your saved measurements and also recall measurements made in the field Real Time Clock – for automatic time stamping of saved readings Field upgradeable and expandable meter lets you stay current as new capabilities are added Multi-lingual interface Min/Max/Average with Time Stamp to record signal fluctuations Soft keys, scroll buttons and easy navigation control access to secondary functions. 0.025% Basic DC accuracy 100 kHz ac bandwidth True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads. Measure up to 10A (20 A for 30 seconds; 10A continuous) 100 mF capacitance range Temperature function Relative mode to remove test lead resistance from low ohms or capacitance measurements Peak capture to record transients as fast as 250 μs Premium test leads and alligator clips included Optional FlukeView forms enables you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents Optional magnetic hanger allows you to hang the meter for easy viewing while freeing your hands to focus on the job. Limited lifetime warranty CAT III 1000 V / CAT IV 600 V safety rated
Specifications |
Voltage DC | Accuracy | 0.025 % | Range and Resolution | 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
|
Voltage AC | Accuracy | 0.4 %(true-rms) | Range and Resolution | 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
|
Current DC | Accuracy | 0.06 % | Range and Resolution | 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
Current AC | Accuracy | 0.6%(true-rms) | Range and Resolution | 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
Temperature (excluding probe) | Accuracy | 1.0 % | Range and Resolution | -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) |
|
Resistance | Accuracy | 0.05 % | Range and Resolution | 500.00 Ω , 5.0000 k Ω , 50.000 k Ω , 500.00 k Ω , 5.0000 M Ω , 50.00 M Ω , 500.0 M Ω |
|
Capacitance | Accuracy | 1.0 % | Range and Resolution | 1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF |
|
Frequency | Accuracy | 0.005% + 5 | Range and Resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
|
Additional functions/features | Multiple on-screen displays | Yes | True-rms AC bandwidth | 100 kHz | DBV/dBm | Yes | Conductance | 50.00nS | Continuity beeper | Yes | Battery/Fuse access | Battery / Fuse | Peak | 250 μS | Elapse time clock | Yes | Time of day clock | Yes | Min-Max-Avg | Yes | Duty Cycle | 0.01 % to 99.99 % | Pulse Width | 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms | Hold | Yes | Isolated Optical Interface | Yes | Auto/Touch Hold | Yes | Reading memory | Yes | Log to PC | Yes | Interval/Event Logging | Yes | Logging Memory | Up to 10,000 readings |
|
Environmental Specifications |
Operating Temperature | |
Storage Temperature | |
Relative Humidity | | 0% to 90% (0 °C - 37 °C) | | 0% to 65% (37 °C - 45 °C), | | 0 to 45 % (45 °C - 55 °C |
|
Electromagnetic Compatability | |
Vibration | | Random vibration per MIL-PRF-28800f Class 2 |
|
Shock | | 1 meter drop per IEC/EN 61010-1 2nd edition |
|
Safety Specifications |
Overvoltage category | | CAT III 1000 V / CAT IV 600 V safety rated |
|
Agency Approvals | |
Mechanical & General Specifications |
Maximum voltage between any terminal and earth ground | |
Size | | (HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in) |
|
Weight | |
Battery Life | | 100 minimum, 200 hours in logging mode |
|
Battery type | | 6 AA alkaline batteries, NEDA 15A IEC LR6 |
|