High-precision measure three-phase voltage, three-phase current, active power, reactive power,apparent power,power factor
Description:
Intelligent digital instrument be used in electricity grids , automation control system to measure voltage ,current ,active power,reactive power , apparent power, power factor and frequency.They are displayed by LED or LCD. Visual display , High accuracy, Reliable performance, Strong isolation, Anti-Vibration.
Performance Characteristics
High-precision measure three-phase voltage, three-phase current, active power, reactive power,apparent power,power factor,frequency.
Measure the direct and the reverse active and reactive power
Timesharing electric energy, Timesharing timer/stopwatch
LED or LCD display , Local data query
Current and Voltage Conversion Ratio is programmable.
Support RS-485 communication Modbus-RTU treaty.
Auxiliary Power Supply :AC/DC 80V-270V,
Accuracy of measurement | |
Voltage | 0.5degree |
Current | 0.5degree |
Active power | 0.5degree |
Reactive power | 0.5degree |
Power factor | 0.5degree |
Active electric energy | 0.5S degree 0.2S degree |
Reactive electric energy | 1 degree or 2 degree |
Signal Input | |
Mode of connection | three-phase three-wire,three-phase four-wire |
Rated voltage | AC57.7V ,AC 100V,AC220V,AC380V |
Rated current | AC1A ,AC5A |
Overload | Voltage:1.2 times 2 times /1 second(instantaneous) |
Current:1.2 times 10 times /5 second(instantaneous) | |
Power dissipation | Voltage:less than 1VA/phase ;Current :less than 0.4VA/phase |
Impedance | Voltage:more than 300kΩ:Current:Less than 20mΩ |
Frequency | 45-65Hz |
APS | |
Operating Range | AC/DC 80V-270V |
Power dissipation | Less than 4VA |
Function Module | |
Communication interface | No. 1 RS-485 communications,Modbus-RTU treaty |
Baud rate:1200-9600bps ,the default value is 2400bps | |
DI | support 4 dry contacts |
DO | support 3 relay output,capacity AC250V/5A DC30V5A |
Environment | |
Working environment | -10°C- +55°C |
Storage Temperature | -25°C- +70°C |
Relative Humidity | ≤93%, No corrosive gas places |
Altitude | ≤2500m |
Security | |
Insulation Resistance | >100mΩ |
ACW | AC 2KV |
EMC | |
ESD | grade 4 |
EFT | grade 4 |
Surge impact | grade 4 |
Dimension | |
Frame dimension | 120*120; 80*80; 96*48; 96*96; 80*80; 48*48; 120*60; 160*80 |
Hole dimension | 111*111; 76*76; 92*45; 92*92; 68*68; 45*45; 114*56; 152*76 |
Model | Measurement | Extended Function | LED | LCD | Hole dimension | ||||||
Single-phase power | DI | DO | TO | Communication interface | |||||||
RH-D1 | √ | 2 | 2 | 1 | 1 | √ | 152*76 | ||||
RH-D1Y | √ | 2 | 2 | 1 | 1 | √ | |||||
RH-D2 | √ | 2 | 2 | 3 | 1 | √ | 111*111 | ||||
RH-D2Y | √ | 2 | 2 | 3 | 1 | √ | |||||
RH-D3 | √ | 2 | 2 | 3 | 1 | √ | 92*92 | ||||
RH-D3Y | √ | 2 | 2 | 3 | 1 | √ | |||||
RH-D4 | √ | 2 | 2 | 1 | 1 | √ | 114*56 | ||||
RH-D4Y | √ | 2 | 2 | 1 | 1 | √ | |||||
RH-D5 | √ | 2 | 2 | 1 | 1 | √ | 92*45 | ||||
RH-D5Y | √ | 2 | 2 | 1 | 1 | √ | |||||
RH-D6 | √ | 2 | 2 | 1 | 1 | √ | 68*68 | ||||
RH-D6Y | √ | 2 | 2 | 1 | 1 | √ | |||||
RH-D7 | √ | 2 | 2 | 1 | 1 | √ | 76*76 | ||||
RH-D7Y | √ | 2 | 2 | 1 | 1 | √ | |||||
RH-D8 | √ | 2 | 2 | 1 | 1 | √ | 45*45 | ||||
Model | Measurement | Extended Function | LED | LCD | Hole dimension | ||||||
Three-phase power | Multi-rate | Harmonious | Fire Monitor | DI | DO | TO | Communication interface | ||||
RH-3D2 | √ | 4 | 4 | 4 | 2 | √ | 111*111 | ||||
RH-3D2Y | √ | 4 | 4 | 4 | 2 | √ | |||||
RH-3FD2Y | √ | √ | 4 | 4 | 4 | 2 | √ | ||||
RH-3HD2Y | √ | √ | 4 | 4 | 4 | 2 | √ | ||||
RH-3LD2 | √ | √ | 4 | 2 | √ | ||||||
RH-3LD2Y | √ | √ | 4 | 2 | √ | ||||||
RH-3FHD2Y | √ | √ | √ | 4 | 4 | 4 | 2 | √ | |||
RH-3D3 | √ | 4 | 4 | 4 | 2 | √ | 92*92 | ||||
RH-3D3Y | √ | 4 | 4 | 4 | 2 | √ | |||||
RH-3FD3Y | √ | √ | 4 | 4 | 4 | 2 | √ | ||||
RH-3HD3Y | √ | √ | 4 | 4 | 4 | 2 | √ | ||||
RH-3LD3 | √ | √ | 4 | 2 | √ | ||||||
RH-3LD3Y | √ | √ | 4 | 2 | √ | ||||||
RH-3FHD3Y | √ | √ | √ | 4 | 4 | 4 | 2 | √ | |||
RH-3D7 | √ | 1 | √ | 76*76 | |||||||
RH-3D7Y | √ | 1 | √ | ||||||||
RH-3D6 | √ | 1 | √ | 68*68 | |||||||
RH-3D6Y | √ | 1 | |||||||||
RH-3D8 | √ | 1 | √ | 45*45 |
29.SINGLE-PHASE MULTI FUNCTION POWER METER | ||||
Model | Display Mode | Face Frame Size | Hole Size | |
mm | mm | |||
RH-D1 | Single Row LED | 160*80 | 152*76 | |
RH-D2 | Single Row LED | 120*120 | 111*111 | |
RH-D3 | Single Row LED | 96*96 | 92*92 | |
RH-D4 | Single Row LED | 120*60 | 114*56 | |
RH-D5 | Single Row LED | 96*48 | 92*45 | |
RH-D6 | Single Row LED | 72*72 | 68*68 | |
RH-D7 | Single Row LED | 80*80 | 76*76 | |
RH-D8 | Single Row LED | 48*48 | 45*45 | |
RH-D1Y | LCD | 160*80 | 152*76 | |
RH-D2Y | LCD | 120*120 | 111*111 | |
RH-D3Y | LCD | 96*96 | 92*92 | |
RH-D4Y | LCD | 120*60 | 114*56 | |
RH-D5Y | LCD | 96*48 | 92*45 | |
RH-D6Y | LCD | 72*72 | 68*68 | |
RH-D7Y | LCD | 80*80 | 76*76 |
Terminal diagram
The wiring diagram
96*48 SINGLE-PHASE SINGLE ROW MULTICHANNEL LCD DIGITAL DISPLAY ENERGY METER RH-D5Y