Model: YYW-Y(Q) Entirety Type Structure Easy Installation and Movement Fuel: diesel oil or natural gas Matched Italy burner
This kind of Thermal Conduction Oil Furnace is entirety type. All installation have been finished in factory, The customer only need connect the parts in the jobsite according to the technical condition.
The fuel can be diesel oil or natural gas. The matched burner adopts Italy famous brand.
The output: 150,000kcal/h, 300,000kcal/h, 500,000kcal/h, 700,000kcal/h, 800,000kcal/h, 1,000,000kcal/h, 1,200,000kcal/h, 1,500,000kcal/h.
MAIN SPECIFICATION
Type Data Parameters | 180 Y(Q) | 350 Y(Q) | 600 Y(Q) | 820 Y(Q) | 940 Y(Q) | 1200 Y(Q) | 1400 Y(Q) | 1750 Y(Q) |
Rated heat output 104Kcal/h | 15 | 30 | 50 | 70 | 80 | 100 | 120 | 150 |
Designed Pressure MPa | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.7 | 0.7 | 0.6 |
Max. working temperature °C | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 |
Thermal efficiency %≥ | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 |
Cycle flow rate m³/h | 40 | 40 | 60 | 100 | 100 | 100 | 100 | 160 |
Caliber of the pipe connected DN | 65 | 65 | 80 | 100 | 100 | 125 | 125 | 150 |
Total power Kw | 8 | 12 | 18 | 27 | 27 | 36 | 36 | 52 |
Fuel variety | Oil Gas |
Entirety Type Thermal Conduction Oil Furnace
Verified Information This information is Verified by Bureau Veritas and validity period is 2012/08/24 --- 2013/08/24 All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >> Production Capacity:Asphalt Mixing Plant, Hot Recycled Mixing Plant, Bitumen Heating Equipment, Thermal Oil Heater, Bitumen Tanks | 50 Sets/Month | 348 Sets |
Eastern Europe | USD 793,651 | 3.8 |
Southeast Asia | USD 476,190 | 2.3 |
Africa | USD 714,286 | 3.5 |
Mid East | USD 1,984,127 | 9.6 |
Domestic Market | USD 16,666,667 | 80.8 |
Lathe | C6150A, C6140A, CW6180C, CW6263C | 7 | 8.0 | Acceptable |
Shaping Machine | BH6070, NYS-60100 | 2 | 8.0 | Acceptable |
Milling Machine | X6132 | 1 | 8.0 | Acceptable |
Radial Drilling Machine | Z3050/16 | 2 | 8.0 | Acceptable |
NC Cutting Machine | GSJ-4000, GS-4000 | 3 | 8.0 | Acceptable |
Air Plasma Cutting Machine | GSII-4500 | 1 | 3.0 | Acceptable |
Hydraulic Bending Machine | WD67Y-300/500 | 1 | 9.0 | Acceptable |
Rolling Machine | ZDW11 | 2 | 9.0 | Acceptable |
Sawing Machine | GB4035 | 3 | 3.0 | Acceptable |
Automatic Welding Machine | LH4 | 2 | 9.0 | Acceptable |
Shot-Blast Cleaning Machine | Q6925-8 | 1 | 5.0 | Acceptable |
Welding Machine | BX3-500F, NBC-500D | 62 | 9.0 | Acceptable |
Impact Tester | JB-300 | 1 | 12.0 | Acceptable |
Hydraulic Universal Tester | WE-600B | 1 | 12.0 | Acceptable |
Projector | CST-50 | 1 | 5.0 | Acceptable |
Resistant Chamber | SX-5-12 | 1 | 12.0 | Acceptable |
Automatic Temperature Control Instrument | 0-1600 | 1 | 12.0 | Acceptable |
Carbon-Sulfur Analysis Instrument | No Information | 1 | 12.0 | Acceptable |
X-Ray Defect Detector | XXH-3005, XXQ-2005D | 3 | 5.0 | Acceptable |
Analysis Balance | TG278B | 1 | 5.0 | Acceptable |
ISO9001:2008 | Gainshine Assessment, CNAS | 1311Q10678R4M | Scope: Design, Development, Production and Service of Road Machinery, Heat Carrier Pyrogenation Stove and Asphalt Heating Equipment. | 2011/12/08 --- 2014/12/07 | |
ISO14001:2004 | Gainshine Assessment, CNAS | 1311E10232R1M | Scope: Design, Development, Production and Service of Road Machinery, Heat Carrier Pyrogenation Stove and Asphalt Heating Equipment and Related Management Activity. | 2011/12/08 --- 2014/12/07 | |
GB/T28001-2001 | Gainshine Assessment, CNAS | 1311S10169R1M | Scope: Design, Development, Production and Service of Road Machinery, Heat Carrier Pyrogenation Stove and Asphalt Heating Equipment and Related Management Activity. | 2011/12/08 --- 2014/12/07 | |
CE | EURO CERT | CN.CE.0671-09/10 | Asphalt Mixing Plant & AMP500, AMP700, AMP1000, AMP1200, AMP1500, AMP2000, AMP2500, AMP3000, AMP4000, AMP5000, PRD500, PRD1000, PRD1500, PRD2000 | 2010/09/30 --- 2015/09/29 | |
CCC | CQC | 2005010301138979 | Low-Voltage Switchgear Assemblies, In=800A~160A, Icw=10KA; Ue=380V, Ui=380V; 50Hz; IP30 | 2008/01/11 --- 2049/12/31 |
Supervision Test Report | Jiangsu Province Special Equipment Safety Supervision & Testing Institute | Organic Thermal Boiler & YY(Q)W-820Y(Q) | 2012/06/04 |