Realize true high temperature curing; the curing temperature & humidity can reach over 90 C, 98%RH even if there is no steam.
SHX-HX high temperature curing chamber is designed to suit the needs of the high curing process, it has the following characteristics:
l Realize true high temperature curing; the curing temperature & humidity can reach over 90°C,98%RH even if there is no steam supply from the user.
l Accurate control for content of tetra basic lead sulfate grants prolonged battery service life.
l The specially designed air recirculation unit which is differed from the conventional one allows intelligent control for recirculating air rate, shorter curing & drying time and enhanced plate uniformity
Model | SHX-G Type | SHX-HT(high temperature type) | ||
Performance | Curing Cycle | 35~75°C ≥98%RH | 35~95°C ≥98%RH | |
Drying Cycle | Ambient temperature ~85°C | |||
Control accuracy | Temperature:±1~2°C humidity±2%RH | |||
(mm) Overall Dimension | 4000(W)×3500(T)×4200(H) (GI type) 5080(W)×2450(T)×4640(H) (GVI type) | 3300(W)×1600(T)×4500(H) | ||
Work Chamber | 3200(W)×3300(T)×2900(H) (GI type) 4280(W)×2250(T)×2900(H) (GVI type) | 2600(W)×1065(T)×2500(H) | ||
Electricity | electrical heating 52.5~67.5Kw | 67.5Kw | ||
steam heating 7.5~11Kw | 7.5Kw | |||
gas heating: 8.0~11.5Kw | — |
High Temperature Curing&Drying Chamber