Detailed Product Description
these series of coolers have double coil parallel arrayed structure. Rinse liquid flows axially through the inner housing, while cooling liquid flows through the coil tube. They mainly function as coolers for API 682 PLAN 21 or PLAN41. Among them, KMHR-2104/2106 can function as coolers for API682PLAN23 as well.
Performance parameters:
Operation temperature: 375 (max)
Operation pressure: 6.0MPa (max) for inner housing, 0.8MPa (max) for coil tube
Heat exchange area: 0.4, 0.6, 0.8, 1.0, 1.2 m2
Structural features:
1. In accordance with the standard JB/T6631-1993
2. With high efficiency of the reverse heat exchange between cooling fluid and flushing fluid
3. Vertical or horizontal mounting is optional
-------------------------------------------------- ------------------------------
2300 series (Type 2313, Type 2325)
These series coolers have Multi-coil parallel arrayed structure. Cooling liquid flows axially through the inner housing, while, the rinse liquid flows through the coil tube. They mainly function as cooler for API 682 PLAN 23.
Performance parameters:
1. Operation temperature: 375 (max)
2. Operation pressure: 6.0MPa (max) for inner housing, 0.8MPa (max) for coil tube
3. Heat exchange area: 0.13, 0.25 m2
heat exchanger