Meeting the German requirement of active power derating function (100%,60%,30%,0%) pls contact Caddie Pan for detail quotation!
Performance features
Meeting the German requirement of active power derating function (100%,60%,30%,0%)
Reactive power is adjustable. with the power factor ranging from leading 0.9 to lagging 0.9.
Without transformer, maximum conversion efficiency is up to 98.7%.
Wide range of DC voltage input, up to 1000V. Increasing the service life of system to 30 years by using membrane capacitance.
Function of low voltage ride through (LVRT).
Adapt to sever low-temperature environment(reaching -30°C)
Multilingual touch screen monitoring interfac
Auxiliary electrical heating(optional)
Applicable to high altitude, <6000 m (derating is needed for the altitude above 3000 m)
German Rittal cabinet
certificationcertificationEU CE certification and Golden Sun certification
Technical Specifications
MODEL DYG-630KTL
DC SIDE DATA
Max. DC Voltage 1100Vdc
Start Voltage 520V
MPP Voltage Range 500~850Vdc
Min. DC Voltage 500V
Max. DC Power 700kWp
Max. Input Current 1400A
AC SIDE DATA
Rated Output Power 630kW
Max. AC Output Current 1270A
Rated Grid Voltage 315Vac
Grid Voltage Range 250~362Vac
Rated Grid Frequency 50Hz/60Hz
Grid Frequency Range 47~51.5Hz/57~61.5Hz
Output Current THD <3% (at nominal power)
DC Current Injection <0.5% of rated inverter output current
Power Factor 0.9(lagging)~0.9(leading)
SYSTEM
Max. Efficiency 98.7%
Euro Efficiency 98.5%
Protection Degree IP20 (indoor)
Operating Temp. -30~+55°C
Cooling Method controlled forced-air cooling
Relative Humidity 0~95%, non-condensing
Max. Working Altitude 6000m (operation with derating above 3000m)
Display AND COMMUNICATIONS
Display touch screen LCD
Standard Comm. Interfaces RS485
Optional Comm. Interfaces Ethernet/GPRS
MECHANICAL DATA
Dimensions(WxHxD) 2800x2180x850mm
Net Weight 2400kg
Power Plant Invertor -without Transfer