Load Break Switch Indoor High voltage disconnector ( LBS )
Load Break Switch Indoor High voltage disconnector ( LBS )

1.Load break switch for Indoor install 2. IEC 62271Standard 3. ISO 9001:2008

Summary

FN12 is a three-phase H.V switch equipment, which is used for 12KV 50Hz for breaking and switching load current, no-load transformer cable charging current and closing short-circuit current. The load switch with earth switch can switch short-circuit current.

FN12-12DR Load Break Switch-Fuse Combination is made up of FN12-12D load switch and S[]LAJ-12(XRNT[]-10) H.V current limiting Fuse. This switch can break any current till short-circuit current.  Because of the striker of the fuse, the switch can switch off automatically.

Application

It is used for the ring main units and industrial equipment of 12KV and three-phase AC 50Hz to control load and short-circuit current. Because the switch-fuse combination protects transformer equipment more reliably than circuit breaker .It is especially suitable for ring main units, radial distribution and combined transformers.

Standard

a,GB3804-90<3~65KV AC H.V Load switch>

b,GB16926-1997<High-voltage alternating current switch-fuse combinations>(eqv. IEC62271-2002)

c,GB1995-89<AC H.V isolate switch and earth switch>

Techniacl parameter and performances(please see the table)

No. 

Description 

Unit

FN12-12D/630

FN12-12D(R)D/100

1

Rated voltage

KV

12

2

Rated frequency

Hz

50

3

Rated current

A

630

100

4

Lighting impulse resisting voltage

KV

To earth and between poles 75/ across isolating distance 85

5

1min power frequency withstand voltage

KV

To earth and between poles 42/ across isolating distance 48

6

Rated short time withstand current

KA

20(4S)

7

Rated Peak Withstand Current

KA

50

8

Rated closing current(peak)

KA

50

50

9

Rated short-circuit breaking current (prospective value)

KA

 

31.5

10

Max. critical breaking current I2·t

A2S

 

fuse characteristic curve

11

Min. Breaking current

KA

 

fuse characteristic curve

12

Rated transfer current

KA

 

1.5

13

Max. breaking current(reference value)

KA

1.8

14

Braking no-load transformer capacity

kva

1250

15

Rated cable charging current

A

10

16

Rated power load current breaking times

time

≥100

17

Switch-off time of rated power load current switch on-and-off

S

 

>0.06

18

Rated transfer current

KA

20(2S)

20(2S)

19

Rated transfer current

KA

50

50

20

Motor operating power voltage

V

110,220 DC/AC

Operation handle

( function(){ var aBigImageSrc = [ 'http://i01.i.aliimg.com/photo/v2/275454401_1/Load_Break_Switch_Indoor_High_voltage_disconnector.jpg' , 'http://i01.i.aliimg.com/photo/v2/275454401_2/Load_Break_Switch_Indoor_High_voltage_disconnector.jpg' , 'http://i01.i.aliimg.com/photo/v2/275454401_3/Load_Break_Switch_Indoor_High_voltage_disconnector.jpg' , 'http://i01.i.aliimg.com/photo/v2/275454401_4/Load_Break_Switch_Indoor_High_voltage_disconnector.jpg' , 'http://i01.i.aliimg.com/photo/v2/275454401_5/Load_Break_Switch_Indoor_High_voltage_disconnector.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); Load Break Switch Indoor High voltage disconnector ( LBS )

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.