good adhesion excellent resistance to chemicals, water and corrosion. Chinese first brang of paint VOC less than 180g/L.
Product Description | -A two pack epoxy heavy-duty anticorrosive coating and it is characterized by good adhesion and excellent resistance to chemicals, water and corrosion. | |||||||||
-VOC less than 180g/L | ||||||||||
Intended Uses | -For use in heavy-duty anticorrosive areas. | |||||||||
-For steel or tidal range zone of concrete stakes heavy-duty anticorrosion. | ||||||||||
-For interior circulatory water piles of power plant special strengthening anticorrosion | ||||||||||
-For interior wall of steel pipes and concrete of Sewage treatment works, power plants and chemical plants etc. heavy-duty anticorrosion. | ||||||||||
-For works of tap water and water anticorrosion | ||||||||||
Product Information | Volume Solids | 78%±2% | ||||||||
Finish/Sheen | Semi-Gloss | |||||||||
Typical Film Thickness | 500 microns dry (640microns wet) | |||||||||
Theoretical Coverage | 1.6m2/L at typical film thickness | |||||||||
Mix ratio | 3.4:1(volume)7:1(mass) | |||||||||
Method of Application | ||||||||||
Airless Spray | Recommended | |||||||||
| Tip size range | 0.45-0.68mm | ||||||||
| Output pressure | ≥17MPa | ||||||||
Air Spray | Not recommended | |||||||||
Brush/Roller | For small area only | |||||||||
Thinner | Not recommended. Use HX-501 only in exceptional circumstances (volume 5%) | |||||||||
Cleaner | HX-501 | |||||||||
Induction Period | Not necessary | |||||||||
Drying Information | ||||||||||
-5°C | 5°C | 25°C | 35°C | |||||||
Touch Dry | 4h | 2h | 1h | 45min | ||||||
Hard Dry | 48h | 36h | 20h | 10h | ||||||
Pot Life | 4h | 2h | 1h | 40min | ||||||
Overcoating Data Substrate Temperature | ||||||||||
Overcoated by 725-H45-ZF101G | -5°C | 5°C | 25°C | 35°C | ||||||
Min Max | Min Max | Min Max | Min Max | |||||||
48h 14d | 36h 10d | 20h 7d | 10h 5d | |||||||
725-J43-5 | 48h - | 36h - | 20h - | 10h - | ||||||
Storage | Store in cool and dry conditions. Well ventilate. Keep away from hot and fire. Shelf Life: 12 months minimum at 25°C. Subject to re-inspection thereafter | |||||||||
Pack Size | Part A | 30kg/15.5L in 20L container | ||||||||
Part B | 4.3kg/4.5L in 6L container | |||||||||
Flash Point | Part A | Greater than 31°C | ||||||||
Part B | Greater than 29°C | |||||||||
Mixed paint | Greater than 31°C | |||||||||
Systems and Compatibility | Consult your Sunrui Representative for the systems best suited for the surfaces to be protected. | |||||||||
Surface Preparation | High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning. All surfaces to be coated should be clean, dry and free from contamination. steel Remove weld spatter and smooth weld seams and sharp edges. The surfaces should be blast cleaned to Sa2.5(GB/T 8923-1988).The weld seams areas could be cleaned to St3(GB/T 8923-1988)using power tool. Apply 725-H45-ZF101G before oxidation occurs. If oxidation has occurred, the entire oxidized area should be reblasted to the standard specified above. concrete Remove loose powder of the cement, attached organisms, mud, oil or grease and other foreign matter thoroughly. The surface can be abrade by blasting or using power tool to remove loose powder, attached organisms, mud etc. and oil can be cleaned by scour. Repair/Maintenance steel The areas to be repaired should be cleaned to St3(GB/T 8923-1988)by mechanical method or higher level of surface prepared to Sa2.5(GB/T 8923-1988)by abrasive blasting. Abrade the area immediately surrounding the repair to provide a key for subsequent coating application. Overlap areas should be kept to a minimum. | |||||||||
Limitations | Apply in good weather. Temperature of the surface to be coated must be least 3°C above the dew point when the is lower than 85%. In common with all epoxy base coatings, 725-H45-ZF101G will exhibit chalking of the firm on UV exposure. The dry time and overcoating interval may change according to the environment factors. Avoiding absorb the solvent steam and paint steam for long time. Skin and eyes must avoid contacting the paint. Pay attention to ventilate and fireproof when applying. |
( function(){ var aBigImageSrc = [ 'http://i01.i.aliimg.com/photo/v2/391691843_1/725_H45_ZF101G_Heavy_duty_anticorrosive_paint.jpg' , 'http://i01.i.aliimg.com/photo/v2/391691843_2/725_H45_ZF101G_Heavy_duty_anticorrosive_paint.jpg' , 'http://i01.i.aliimg.com/photo/v2/391691843_3/725_H45_ZF101G_Heavy_duty_anticorrosive_paint.jpg' , 'http://i01.i.aliimg.com/photo/v2/391691843_4/725_H45_ZF101G_Heavy_duty_anticorrosive_paint.jpg' , 'http://i01.i.aliimg.com/photo/v2/391691843_5/725_H45_ZF101G_Heavy_duty_anticorrosive_paint.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); 725-H45-ZF101G Heavy-duty anticorrosive paint