BANTE900 pH Meter, ORP Meter, Ion Meter, Conductivity Meter, DO Meter (CE Certification)
BANTE900 pH Meter, ORP Meter, Ion Meter, Conductivity Meter, DO Meter (CE Certification)

* Multiparameter testing are available * Multi-point Calibration * Using the British Electrode * Store up to 99 Data Sets

BANTE900 meter is capable of measuring up to 8 water quality parameters, including pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen and temperature.

Multi-point Push-button Calibration:The meter has multi-point calibration mode. From setup menu, choose calibration and immerse electrode sensor into indicated calibration solution, press ENTER key and meter is automatically calibrated.

Auto-Buffer Recognition:During calibration, if the calibration solution does not match the meter's indicated value, an ERROR message is displayed.

Viewing of Electrode Slope:After pH or ion calibration, the percentage slope of the sensor is displayed before the meter returns to measurement mode. Per the slope value, user decides whether to change electrode.

Automatic Temperature Compensation:The meter provides automatic temperature compensation mode for optimum accuracy under variable temperature conditions. Insert the temperature probe into meter, the temperature value will automatically displays on the screen.

Ion Concentration Measurement:Bante900 meter has 13 types of ion measurements to choose. From the setup menu select the desired Ion type and press the ENTER key. The pX value is displayed, Use ENTER key again to switch between pX, ppm, mg/L values.

Auto-Ranging for Conductivity:The meter has auto-range functions for measuring conductivity and total dissolved solids (TDS). Upon immersing conductivity

sensor into sample solution, the screen immediately displays the value in appropriate measurement range for accuracy.

Adjustable Temperature Coefficient:Various ions in solution have different temperature coefficients. BANTE900 meter can set the temperature coefficient between 0 and 3.9% in degrees centrigrade for optimum accuracy.

Adjustable Cell Constant:The meter has three cell constants for measuring requirements. Once a cell constant has its calibration set, it is saved and does not require re-calibration when switching electrodes.

Salinity and Barometric Pressure Compensation:During the Dissolved Oxygen modes, Salt dissolved  in solution will be limits oxygen content, Bante900 meter can compensates the salinity and barometric pressure after manual input coefficients.

Message Indicator:BANTE900 meter has message indicators, it can shows many helpful messages like an on-screen manual for easy operation.

Communication Interface and Data Store:The meter has real-time date/clock stamps, the memory stores up to 99 data sets. Press the SAVE key to store the current

measured values and it automatically generates a serial number with time. All of stored data can then be sent to a computer

via the USB port.

  

Specifications:pH Mode:pH Range: -2.000 to 16.000pHpH Accuracy: ±0.002pHCalibration Points: 2 points, NIST(pH4.00/6.86/9.18) or USA (pH4.01/7.00/10.01)Temperature Compensation: 0.0 to 100.0°C, 32 to 212°F, Manual or Automatic

ORP Mode:ORP Range: -1999.9 to +1999.9mVORP Accuracy: ±0.2mVCalibration Points: 1 point

Ion Mode:Ion Concentration Range: 0 to 19999ppm (Based on ISE Range)Ion Concentration Accuracy: ±0.5% F.S (Monovalent), ±1% F.S (Divalent)Calibration Points: 2 to 5 pointsTemperature Compensation: 0.0 to 100.0°C, 32 to 212°F, Manual or Automatic

Conductivity/TDS/Salinity/Resistivity Modes:Conductivity Range: 0 to 1.999, 19.99, 199.9, 1999uS/cm, 19.99, 200.0mS/cmConductivity Accuracy: ±0.5% F.SCalibration Points: 1 point per rangeTemperature Compensation: 0 to 50°C, 32 to 122°F, Manual or AutomaticTemperature Coefficient: 0 to 3.9% per °CCell Constant: 0.1, 1.0, 10 (Adjustable)TDS Range: 0 to 100ppt, Max.200pptTDS Accuracy: ±1% F.STDS Conversion Factor: 0.01 to 1.00, Default 0.67Salinity Range: 0 to 50ppt, 0.00 to 5.00%Salinity Accuracy: ±0.5ppt, ±0.05%Resistivity Range: 0 to 100MΩResistivity Accuracy: ±1% F.S

DO Mode:Dissolved Oxygen Range: 0.00 to 20.00mg/L or ppmDissolved Oxygen Accuracy: ±0.3mg/L or ppmSaturation of Oxygen: 0 to 200.0%Accuracy: ±5.00%Temperature Compensation: 0 to 40°C, 32 to 104°F, AutomaticSalinity Correction: 0 to 35g/LBarometric Pressure Correction: 450 to 850mmHg, 60 to 112.5kpaCalibration Points: 1 or 2 points (100% in air or 0% in zero oxygen solution)

General Parameters:Temperature Range: 0.0 to 100.0°C, 32 to 212°FTemperature Accuracy: ±0.3°C, ±0.5°FMemory: 99 data sets with date/time stampingOutput: USB Communication InterfacePower Requirements: DC 9V, using AC adapters 220VAC, 50HzDimensions: 210(L)×188(W)×60(H)mmWeight: 1.7kg

Meter Included: pH Electrode (Made in UK), Conductivity Cell, DO Probe (Made in US), Temperature Probe, Power Adapters