S11-30KVA 33kv/0.4kv oil immersed distribution transformer
S11-30KVA 33kv/0.4kv oil immersed distribution transformer

1. oil immersed power distribution transformer 2. Accords to GB/T7595 JB/T3837-1988 IEC60076 3. three years warranty

S11 type Oil immersed distribution transformer of 35KV

1/ basic parameters

Type: S11 33KV 35KV Series

Rated capacity: 30 KVA

Voltage combination:

13.8KV/0.4KV ;15KV/0.4KV; 20KV/0.4KV; 22KV/0.4KV; 33KV/0.4KV; 35 KV/ 0.4KV

33KV/10KV 33KV/6.3KV 35KV/10KV 35KV/6.3KV

Conncc-tiojjosymbol: D/Yn11 OR Yyn0

Load loss: 1.1KW

No-load loss: 0.23 KW

Non-load current: 2.3%

Short-circuit impedance: 6.5%

Oil weight: 210KG

The total weight:670KG

Size long: 1000 mm

Size wide: 800 mm

Size high: 1415 mm

Installation size: 550 * 550 mm

Normal packing standard:1PCS/CTN 14PCS/20’ 28PCS/40’

2/ the use of the environment

Device types: outdoor type

Normal environment conditions of use: the elevation not more than 1000 m

Environmental highest temperature + 40°C, minimum-25°C

The special environment conditions of use: elevation of more than 1000 m

Environmental highest temperature + 40°C, minimum-45°C. (when you order details)

Mounting ambicnt: no corrosive gas, no obvious dirt environment

3/ carries out the standard

1. IEC60076 power transformer   distribution transformer

2. GB1094.3, 5-2003 power transformer

3. GB/T6451-2008 oil-immersed three-phases transformer power technical parameters and requirements

4. GB1094.1 ~ 2-1996 power transformer

4/ performance characteristics

1, S11 series power transformer core USES the high quality cold-rolled steel coil, USES the high quality anaerobic copper into and beautiful outlook, safety of operation. S11 series S9 series transformer and compared, and the annual average no-load loss is reduced by 10% and the average load loss is reduced by 20% and save energy obviously, widely used in industry and agriculture, urban and rural power grid.

2. High reliability, performance level advanced, economical index is reasonable.

3. The core of the level 3 juncture when, surface coating cured paint, in order to reduce loss and noise.

4. Winding new structure, reasonable design oil way, adopt new insulation structure, improve mechanical strength and resistance to short

S11-30KVA 33kv/0.4kv oil immersed distribution transformer