Insulating properties of these two materials are in line with requirements of national standard GB/T8815-2008
Technical data sheet
Test Items | Unit | Technical Requirements | |
H-901 | H-902 | ||
Tensile strength | MPa | ≥16 | ≥16 |
Elongation at break | % | ≥180 | ≥180 |
Oven aging condition | °C·h | 100×240 | 100×240 |
Tensile strength | MPa | ≥16 | ≥16 |
Variable rate of tensile strength | % | ≤±20 | ≤±20 |
Elongation at break | % | ≥180 | ≥180 |
Variable rate of elongation | % | ≤±20 | ≤±20 |
weight loss (100°C×168h) | g/m2 | ≤15 | ≤15 |
Low temperature brittleness | °C | -20 | -20 |
20°C Volume resistivity | Ω·m | ≥1.0×109 | ≥1.0×109 |
Dielectric strength | MV/m | ≥18 | ≥18 |
Oxygen index | % | ≥25.5 | ≥30 |
Density | g/m3 | ≤1.40 | ≤1.45 |
200°C Thermal stable time | min | ≥80 | ≥80 |
Hot deformation | % | ≤40 | ≤40 |
Product