Welcome to ECBAY
400mA Medical X-ray machine YSX0115
400mA Medical X-ray machine YSX0115

400mA Medical X-ray machine YSX0115 1 400mA medical x-ray machine 2 medical x-ray equipments 3 medical x-ray unit

Medical X-ray machine YSX0115

1 Equipped with single diagnostic table and x-ray rubes, single direct bridge full-wave commutation, tube voltage is 125kV, tube currency is 400mA.

2 X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protectorate provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.

   3 Bigger scope of rotation diagnostic table, movable table muli-item spot-film device, easy to operate, radiation –proof, ensure operate and the tested.4 Radiography table can move lengthways and crossover, can loaded all kinds of radiography dark box, use conveniently and it is beautiful.5 Applied in all kinds of hospital for radiography such as general body,beam filtration,and chest.

Department

Technology parameters

 

High voltage generator control table and high voltage transform assemble

Fluoroscopy

Tube currency

0.3-5mA continuous currency

 

Tube voltage

45-110KV continuous voltage

 

Radiography

Tube currency

50-400mA shift

 

Tube voltage

45-125KV continuous voltage

 

Exposure time

0.03-5s,23 shift

 

Power

Voltage

380V±10%

 

Frequency

50Hz±1Hz

 

Capacity

≥30KVA

 

Inner resistance

≤0.3Ω

 

X-ray assembly

Type of x-ray

XD51-20.40/125

 

Focus

1×1.2×2 double focal

 

Rated rotate speed of anode

2800r/min

 

CDGI Multi function   radiography table

Moving table

Lengthways

±600mm

Electromagnetism locking

 

Across

±120mm

 

Mobile beam filtration grid

Grid density

28L/cm

 

Grid ratio

8:01

 

Focusing distance

100cm

 

Scope of moving

≥600mm

 

Radiography item

5”×7”,8”×10”,10”×12”,11”×14”,

 

12”×15”,14”×14”,14”×17”

 

Distance from surface to film

75mm

 

Height of bed

700mm

 

Moving pillar

±180°,per 90°orientation, moving lengthways ≥1500mm

 

Bulb tube

Rotate the cross arm±180,ascend $ descend 1100mm

 

Option

 

 

LSJ pillar radiography frame

The scope of ascend and descend

1450mm

 

The minimum distance from focal spot

380mm

 

Radiography item

8”×10” 10”×12” 11”×14”      12”×15”14”×14” 14”×17”

 
 

Fixed beam filtration role

Grid density

40L/cm

 

Grid radio

10:01

 

Focal distance

180cm

 

400mA Medical X-ray machine YSX0115

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.