Welcome to ECBAY
2012 NEW RF Slimming and Body shaping Cavitation Beauty Equipment
2012 NEW RF Slimming and Body shaping Cavitation Beauty Equipment

1)Cavitation Beauty Equipment 2)Power supply:AC230V 10,50Hz 1Hz/AC110V10,60Hz 1Hz 3)Vacuum RF roller 4)40KCavitation

2012 NEW RF Slimming and Body shaping Cavitation Beauty Equipment   

1. TREATMENT THEORY:

1).Slimming and Body Shaping:

Radio frequency and Infrared light (700-2000nm) focus on heating the epithelial tissue and connective tissue; infrared light heats tissue up to 5mm while radio frequency from 5mm to 15mm in depth which effectively increase the oxygen driven, strengthen the material exchange into and out of cells and promote fat metabolism. Infrared light increases tissue elasticity, heats subcutaneous fat and shrinks fat cells while protecting epidermis. Vacuum facilitate blood flow and catalytic enzyme release for fat metabolism. The synergistic combination of Radio frequency and infrared light with vacuum highly increases fat metabolism within the mitochondria, for an instant body reshaping.

2).Cellulite Reduction and Skin Tightening:

The synergistic combination of RF (radio frequency), IR (Infrared light), Roller and Vacuum increases blood circulation and oxygen intracellular diffusion on partial tissue and increases lymphatic drainage hence effectively reduces cellulite. Optimal hyperthermia penetrates into subcutaneous tissue to activate fibroblast of connective tissue and increase collagen and elastic fibers, which gives you a smooth, young skin.

 2. APPLICATION:1).Cellulite reduction. 2). Double chin eliminating, Face lifting. 3). Skin Tightening. 4). Remodeling exquisite shape. 5). Post-baby treatment. 6). Body reshaping after post-liposuction treatment.7). Get rid of stretch marks, scars

3,Advantage of technology1). Use the highest vacuum RF roller2).Two main Program:A,Roll inside is slimming(Front axle clockwise + rear axle clockwise)B, Roll outside is tightening the skin(Front axle reversal + rear axle reversal)3).  Display Screen:8 "TFT color touch screen 4).During operation, comfortable, non-ache, non-wound5).Easy operate.6).No consumption, low cost, quick return.

 4.Features:1). The entire process is completed without the need of surgery and anesthesia.2). Does not cause the phenomenon of uneven skin.3). Does not cause the phenomenon of bleeding, swelling and blood stasis.4). Without side effects and the risk of gaining the weight back, the results are rather obvious.5). Non-invasive treatment does not affect the normal work and life. 

6,Operation Operation Step:

 1).Check all the parts if have the right connect,clean and disinfection all the parts;Connect the power wire,open the panel-switch,enter the system.2).Clean the operate body, apply the skin products, suggest use vacuum RF roller with ultrasonic fat burning gel ,RF is suitable for body,abdomen,arm,leg,back,buttocks.3).Use 40Khz Ultrasonic cavitation system, thought the fat layer by strong waves, speed vibration deep stubborn fat in fat cells produce countless vacuum air inside and outside the hole, strong impact of fat cells, so that fat cells within the blast, broken down into free fatty acids.(Prohibit the use of this function above the neck, the time control in 10-20 minutes)4).To avoid the bone-bit, fixed on the treatment position, using the energy of the electrode plate electrodes, electronic collaboration in a variety of physical interaction, the corresponding points to stimulate the body, burns calories and fat again.5).Stop the mamchine when the operation is ended, turn off the main power supply,clean all parts, and put the machine into origin place.

7,Machine system:

1).Connect the power, turn on the instrument panel-switch, the machine displays: (Please select and enter the menu)

2).vacuum RF roller.

A. According to the client's physical condition and treatment site, set treatment: treatment time; mode selection; energy intensity. Power set according to customer specific circumstancesB. Then click "Start/pause",when the time start count down, it means this function start working.C. After treatment, click “Start/pause” again, when the time stop, it means this function stop working.D. Then click "back"to menu

Note:[RF] mark RF;   [Select] mark absorption and desorption mode;[Power] mark Absorption and desorption pressure;  [Time] mark working time[Start/Pause] mark start and pause

 3). 40KHZ Ultrasonic Cavitation System

 A. According to the client's physical condition and treatment site, set treatment: treatment time; mode selection; energy intensity.  Power set according to customer specific circumstances.

B. Then click'Start/pause', when the time start count down, it means this function start working.C. After treatment, click “Start/pause” again, when the time stop, it means this function stop working.D. Then click 'back' to menu

4). Positioning explosion fat pad:

A. According to the client's physical condition and treatment site, set treatment: treatment time; mode selection; energy intensity.  Power set according to customer specific circumstances.B. Then click"Start/pause'" when the time start count down,  

10,Packing List and Technology parameters

Technology parameters

1. Display Screen: 8 "TFT color touch screen

2. Work method: Pulse form   Pulse width:0.5s-7.5s

3. Negative pressure: Absolute size 60kPa -10kPa(7.6cmHg -60.8cmHg)

Relative value size  20kPa-90kPa(15.2cmHg-68.4cmHg)

4. Pump flow: 60L/min.

5. Roller speed:0-55rpm6. Roller working modes: 2

7. RF Frequency: 1-10MHz   8. RF energy density: maximum 60J/cm3

9. Cavitation frequency:  35KHz-45KHz

10. Power: 300W-500W

11. Power supply:  AC230V±10%,50Hz±1Hz/ AC110V±10%,60Hz±1Hz

 11,Caution

1.Pregnant women or women during in menses.2.Epileptic3.Patients with malignancy.4.Patient whose wound after operation has not healed up.5.Acute inflammation or epidemical patients.6.Whom with heart diseases or with heart pacemaker..7.Whom with kidney (gall-stone ) disease.8.Who was embedded metal object or silica gel.9.Who in menses, birth control period, emiction incontinence period, or accepting the belly operation.10.Whose body always take much inner hot.11.Who has the genetic hypersensitivity.

NNot use the cavitation Head on our head(above neck) ,not use it on Glottis and sexual organs2.Be sure to use the special ultrasonic gel.3.Avoid knocking the head.4.For avoiding burning the head, during operation, please prepare enough ultrasonic gel.5.Don't stay in one place, avoid treating on the bone.6.Don't use disinfectant product to disinfect the head. We suggest the wet cotton or dry towel enough.7.Check the machine power cord if it is connected well.8.If the machine will not use for a long time, please switch off it, and power off.9.Please take off all metal decoration from the operator and patient's body.10.If continuous using 1 hour, please pause the machine about 10 minutes, then using again.11.During the operation, be sure not to accept other treatment.OTICE

2012 NEW RF Slimming and Body shaping Cavitation Beauty Equipment

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.