Welcome to ECBAY
DR series 120w guide rail switching power supply
DR series 120w guide rail switching power supply

can be installed on DIN rail: TS-35/7.5or TS-35/15

Guide rail type switching power supply 120W

Features:                                                                                                                                                                                                                        

·Universal AC input ·Small volume,low weight,high efficiency                                                                                                                                        ·Protections: short circuit/over load/over voltage·Cooling by free air convectio·Can be installed on DIN rail: TS-35/7.5or TS-35/15·LED indicator for power on·100% full load burn-in test·2 Year warranty 

DR-120W
ModelDR-120-12DR-120-24DR-120-48
Output DC voltage12V24V48V
 Voltage tolerance±2%±1%±1%
 Rated current8.3A5A2.5A
 Current range0~8.3A0~5A0~2.5A
 Rated power99.6W120W120W
 Ripple&noise100mvp-p120mvp-p150mvp-p
 DCvoltage ADJ.range-9%~+10%±10%±10%
Input Voltage range90~264VAC, 127~373VDC
 Frequency47~63Hz
 AC current2.6A/110VAC, 1.6A/220VAC
 Efficiency82%84%85%
 Inrush currentCold start current  25A/110VAC,45A/220VAC
 Leakage current< 1mA/240VAC
Protection Over loadabove 105%~135% rated power
protection type:rated current limit,auto-recovery after fault condition is removed
 Over voltage15.6~17.8V30.6~33.2V54.8~56.6V
protection type:cutoff output, recovery after restart power
Environment Working temp,humidity-20°C~+60°C, 20%~90%RH
 Storagetemp,humidity-40°C~+85°C,10%~95%RH non-condensing
 Withstand vibration10~500Hz, 2G 10min/1cycle, period for 60 minutes, each axes
Safety Withstand voltageI/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC
Fitstandard Safety standardFit UL1012
 EMC standardmeet EN55022, CLASSA
Others Dimension65.5*125.2*100mm (L*W*H)
 Weight/packing0.8kg/20pcs/17kg/0.046m³/1.64CUFT
Note 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
 3. Tolerance : includes set up tolerance, line regulation and load regulation.

DR series 120w guide rail switching power supply

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.