75W Switch power supply(switching mode power supply)
75W Switch power supply(switching mode power supply)

Detailed Product Description


  •           China manufacture 75W switch model power supply
  •           Low price and high reliability
  •           AC input power suitable for the world
  •           High efficiency and low operation temperature
  •           Soft-start current can reduce the AC input impact effectively
  •           With Short-circuit and overload protection
  •           100% full-load burning test
  •           Installed with EMI filter, minimum wave.
  •           2 years warranty

 

Model

S-75-12

S-75-15

S-75-24

DC output voltage

12V

15V

24V

Output voltage errorNote2

±1%

±1%

±1%

Rated output current

6.3A

5A

3.2A

Output current rage

0-6.3A

0-5A

0-3.2A

Wave and noise(Note 3

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note 4

±0.5%

±0.5%

±0.5%

Load stability (Note 5

±0.5%

±0.5%

±0.5%

DC output power

75W

75W

75W

Efficiency

78%

78%

82%

Adjustable range for DC voltage

+10%

+10%

+10%

AC input voltage range

90~132VAC/180-264VAC selected by switch 47-63Hz120-370VDC

Input current

1.6A/115V 0.8A/230V

AC Inrush current

Cold-start current 18A/115V 36A/230V

Leakage current

<1mA/240VAC

Overload protection

105%~150% Tpye:pulsing hiccup shutdown Reset: auto recovery

Temperature coefficient

±0.03%/(0~50%)

Setup rise hold up time

800ms,50ms,10ms/115V 300ms,50ms,80ms/230VAC

Vibration

10-500HZ,2G 10min,/1cycle,Period for 60min,Each axes

Withstand voltage

Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistance

Input and output internal: Input and enclosure, Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10~+60Refer to output derating curve,20%~90%RH

Store temperature and humidity

-20~+85,10%~95%RH

Overall dimension

159×98×38mm

Weight

0.5Kgs

Safety standards

UL1012 TUV EN6050(IEC,UL1950)Approved

EMC standards

CISPR22(EN55022),IEC801-2,3,4,IEC555-2 Verification

Note
1.The testing condition for the parameter above is :230VAC input, rated load,2570% RH.Humidity.
2. Error.include the setting error, line stability and load stability. (Note: 5).
3.Wave test: adopting "A12"double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.
5. Load stability test: the load is from 0% to 100%.