Switching Power Supply 100W Model:S-100-5(7.5,10,12,15,18,24,27,48) Output voltage:5,7.5,10,12,15,18,24,27,48V
Switching Power Supply 100W
Features:AC input range selectable by switchProtections: Short circuit/Over loadCooling by free air convection100% full load burn-in testFixed switching frequency at 25KHzLow costHigh reliability
SPECIFICATION: | ||||||||||
MODEL | S-100-5 | S-100-7.5 | S-100-10 | S-100-12 | S-100-15 | S-100-18 | S-100-24 | S-100-27 | S-100-48 | |
OUTPUT | DC VOLTAGE | 5V | 7.5V | 10V | 12V | 15V | 18V | 24V | 27V | 48V |
RATED CURRENT | 20A | 13.6A | 10A | 8.5A | 6.7A | 5.6A | 4.5A | 3.7A | 2A | |
CURRENT RANGE | 0 ~ 20A | 0 ~ 13.6A | 0 ~ 10A | 0 ~ 8.5A | 0 ~ 6.7A | 0 ~ 5.6A | 0 ~ 4.5A | 0 ~ 3.7A | 0 ~ 2A | |
RATED POWER | 100W | 102W | 100W | 102W | 100.5W | 100.8W | 108W | 99.9W | 96W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
VOLTAGE ADJ. RANGE | 4.75 ~ 5.5V | 6.75 ~ 8.25V | 9 ~ 11V | 10.8 ~ 13.2V | 13.5 ~ 16.5V | 16.2 ~ 19.8V | 21.6 ~ 26.4V | 24.4 ~ 29.7V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% | |
SETUP, RISE, HOLD TIME | 200ms, 80ms, 20ms at full load | |||||||||
INPUT | VOLTAGE RANGE | 85 ~ 132VAC/180 ~ 264VAC selected by switch 255 ~ 370VDC | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
EFFICIENCY (Typ.) | 78% | 80% | 80% | 81% | 81% | 82% | 84% | 84% | 84% | |
AC CURRENT | 2.4A/115VAC 1.2A/230VAC | |||||||||
INRUSH CURRENT (max.) | COLD START 30A/115VAC 60A/230VAC | |||||||||
LEAKAGE CURRENT | <1mA / 240VAC | |||||||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power (150 ~ 200% rated output power for S-100-7.5 only) | ||||||||
Protection type: Shut down o/p voltage, re-power on to recover. |