Switching power supply 1.100% full load burn in test 2.high conversion rate,low temperature 3.High quality, prompt delivery
S-50 Switching Power Supply1.Input current:1.6A/115V/ 0.8A/230V2.AC Inrush current:20A/115V 40A /230V3.Leakage current:< 3.5mA/240VAC
Model Specification | S-50-5 | S-50-12 | S-50-24 |
DC output voltage | 5V | 12V | 24V |
Output voltage range(Note:2) | ±1% | ±1% | ±1% |
Rated output current | 10A | 4.2A | 2.1A |
Output current range | 0-10A | 0-4.2A | 0-2.1A |
Wave and noise(Note:3) | 70mvp-p | 100mvp-p | 100mvp-p |
Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.5% |
Load stability(Note:5) | ±0.5% | ±0.5% | ±0.5% |
DC output power | 50w | 50.4w | 50.4w |
Efficiency | 73% | 81% | 84% |
Adjustable range for DC voltage | 4.5~5.5v | 10.5~13.2v | 21.5~27v |
AC input voltage range | 85~132VAC/176-264VAC selected by switch 47~63Hz;248~370VDC | ||
Input current | 1.6A/115V/ 0.8A/230V | ||
AC Inrush current | 20A/115V 40A /230V | ||
Leakage current | <3.5mA/240VAC | ||
Overload proctection | 105%~150% Type:pulsing hiccup shutdown Reset:auto recovery | ||
Over-voltage protection | 115%~135% Type:pulsing hiccup shutdown Reset:auto recovery | ||
High-temperature protection | >=800C~850C,Cut off output(5~15V)~(24~48V) | ||
Temperature coefficient | ±0.03%/0C(0~500C) | ||
Setup,rise,hold up time | 200ms,100ms,20ms | ||
Working temperature and humidity | -100C~+600C(Refer to output derating curve),20%~90%RH | ||
Srore temperature and humidity | -200C~+850C,10%~95%RH | ||
Overall dimension | 159×98×38mm | ||
Weight/packing | 0.5kgs, 30pcs/16KG | ||
Safety standards | Design refer to UL 1950 | ||
EMC standards | Desgn refer to FCC Part15J classA |
Specific parameters can be customized according to customer requirements