50W triple output swithcing power supply T-50 for good quality 1.LED indicator for power on. 2.Cooling by free air convection
50W triple output swithcing power supply T-50 for good quality
1. Universal AC input/ full range
2. Protections: short circuit/ overload/ over voltage
3. Cooling by free air power on
4. 100% full load burn-in test
5. LED indicator for power on
6. All using 105°c long life elctrolytic capacitors
7. Withstand 300VAC surge input for 5 second
8. High operating temperature up to 70°c
9. Withstand 5G vibrtion test
10. High efficiency, long life and high reliablity
11. 3 years warranty
Model Specification | T-50A | T-50B | T-50C | T-50D | ||||||||
CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
DC output voltage | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 15V | 24V |
Output voltage error (Note2) | ±2% | ±5% | ±5% | ±2% | ±5% | ±5% | ±2% | ±5% | ±5% | ±2% | ±6% | ±6% |
Rated output current | 7A | 1A | 1A | 5A | 1A | 1A | 4A | 1A | 1A | 3A | 1A | 1A |
Output current rage | 0.6-7A | 0.2-1A | 0.2-1A | 0.6-5A | 0.2-1A | 0.2-1A | 0.6-4A | 0.2-1A | 0.2-1A | 0.6-4A | 0.2-2A | 0.2-1A |
Wave and noise(Note3) | 100mV | 100mV | 100mV | 100mV | 100mV | 100mV | 100mV | 100mV | 100mV | 50mV | 120mV | 120mV |
Inlet stability(Note4) | ±0.5% | ±0.5% | ±0.5 | ±0.5% | ±0.5% | ±0.5 | ±0.5% | ±0.5% | ±0.5 | ±0.5% | ±1% | ±1% |
Load stability(Note5) | ±1% | ±4% | ±4% | ±1% | ±4% | ±4% | ±1% | ±4% | ±4% | ±1% | ±5 | ±5% |
DC output power | 52W | 49W | 50W | 51W | ||||||||
Efficiency | 66% | 69% | 71% | 72% | ||||||||
Adjustable range for DC voltage | CH1+10,-5% | CH1+10,-5% | CH1+10,-5% | CH1+10,-5% | ||||||||
AC input voltage range | 85~132VAC/170~264VAC selected by switch 47~63Hz;240~370VDC | |||||||||||
Input current | 1.6A/115V 0.8A/230V | |||||||||||
AC impulse current | Cold-start current 20A/115V 40A/230V | |||||||||||
Leakage current | <0.5A/240VAC | |||||||||||
Overload protection | 105%~150% Type:PULSING HICCUP SHUTDOWN Reset auto recovery | |||||||||||
Over-voltage protection | …… | |||||||||||
High-temperature protection | ||||||||||||
Temperature coefficient | ±0.03%°C(0~50°C) ON+5V OUTPUT | |||||||||||
Setup rise hold up time | 200ms,50ms,16ms | |||||||||||
Vibration | 10~500Hz,2G 3AXES 10min./1cycle,Period for 60min,Each axes | |||||||||||
Withstand voltage | Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | |||||||||||
Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure:500VAC/100M Ohms | |||||||||||
Working temperature and humidity | -10°C~+60°C,20%~90%RH | |||||||||||
Store temperature and humidity | -20°C~+85°C,10%~95%RH | |||||||||||
Overall dimension | 159*97*38mm | |||||||||||
Weight | 0.54Kgs | |||||||||||
Safety standards | Meet UL1012 requirement(Not apply for the mark) | |||||||||||
EMC standards | …… | |||||||||||
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25°C 70%Rh,Humidity2.Error,include the setting error, line stability and load stability.(Note:5)3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.5.Load stability test: The load is from 0% to 100%,others 60%.6.C2,3,11must be knocked down. |
50W triple output swithcing power supply T-50 for good quality