Welcome to ECBAY
HPC-602 Portable Smoke opacimeter
HPC-602 Portable Smoke opacimeter

HPC-602 Portable Smoke opacimeter Use of "air curtain" technology to protect the optical system from contamination

HPC-602 Portable Smoke opacimeter

Main Features:

Separated structural design, operation more convenient and more accurate data.

Adopted a triage-type sampling technique, diesel engine acceleration, deceleration, and steady speed can be measured when the smoke;

Linear automatic data processing, can be displayed opacity degrees N, light absorption coefficient K and the corresponding value of filter paper-type smoke SF;

High-brightness digital display;

Use of "air curtain" technology to protect the optical system from contamination;

Automatic detection of room temperature control, anti-condensation can affect the test accuracy;

Automatically attached to the time display; optional speed measurement and oil temperature measurement

Show where the failure of automatic diagnosis unit;

Equipped with built-in printer (or digital RS-232A interface or analog interface);

In line with ISO11614 and GB3847-2005 technical requirements.

Main technical parameters:

Test Scope:

No light transmission N::0~100% (equivalent to smoke value 0 ~ 10FSN)

Light absorption coefficient K:0-16 .06 m-1

RPM:0-9990rpm OIL TEMP: 0-150°C

Indication error of +/- 2% ( measured value)

Stability of automatic zero adjustment, moment drift less than+/-1% / 4H

Repeatability repetition error of+/-1%

Resolution: N:0.1%, K:0.01m-1 ,RPM:10rpm, OIL TEMP:0.1°C

Output mode: digital direct reading, can be attached to the printer to print the smoke concentration ( darkness) maximum value, test time, date. Can interface with computer networking

Measurement of smoke temperature of 70 degrees C ( automatic thermostat ), when the temperature error = + 10%, temperature and error indicator light

Environmental conditions of temperature -5 to 50 DEG C, relative humidity 90%

AC100-240V 50/60Hz 150VA power source power consumption

Dimensions ( including bracket) control portion of the 240mm (L) x 310mm (W) x 170mm (H)

Light path part 130mm (L) x 400mm (W) x 390mm (H)

Weight control section 4kg

Light path part 5kg

HPC-602 Portable Smoke opacimeter

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.