FDL16-D Electric Timer switch 1)Switching: reset after 30s 2) with good quality and suitable 3)Consumption: 1VA
1.Construction and Feature
1.1.Suitable to control wide range lightings include incandescent lamp,halogen
1.2.fluorescent lamp1.3.Simple time setting1.4.With time delay1.5.Extremely compact and modular size
2.Application
The time switch, applicable to circuit with rated voltage 230V AC and rated current 16A, “opens” after a predetermined time from actuation.
3.Technical Data
3.1.Rated voltage: 230V~3.2.Rated frequency: 50Hz3.3.Consumption: 1VA3.4.Contact capacity: 16A 250V AC (COSφ=1)3.5.Electrical endurance: 105 cycles3.6.Mechanical endurance: 107 cycles3.7.Ambient temperature: -20°C~+50°C3.8.Connection terminal: pillar terminal with clamp 3.9.Installation: On symmetrical DIN rail Panel mounting
4.FDT16-M time switch
4.1.Type: electromechanical type with time delay4.2.Time setting range: 7 minutes4.3.Min. setting interval: 30 seconds4.4.Toggle switch: manual/automatic4.5.Controlled lighting load: Incandescent lamp: 2300W Halogen lamp: 2300W4.6.Fluorescent lamp: Uncompensated 2300w Compensated in series: 2300w Compensated in parallel: 1300w4.7.Switching: reset after 30s
5. overall &instation dimensions
(FDT16-M) Electric Timer switch