Welcome to ECBAY
smart syringe pumps 8 channels
smart syringe pumps 8 channels

stackable syringe pump JZB-1800C can be stacked up to 8 channels coupled with any brand syringes kvo and bolus, OEM & ODM  stackable syringe pump JZB-1800Ccan be stacked up to 8 channelscoupled with any brand syringesThree working modekvo and bolus functionOEM available single syringe pump JZB-1800c is a routine used equipment for hospital emergent treatment, cure and nursing. It adopts the new technology of microcomputer with compact structure. It has multi-intelligent alarm functions, could use disposable syringe of many kinds of, strong functions and use convenient. It is especially suitable for exact micro infusion or quick infusion for long time. This product is use for push the syringe to control the liquid amount into patient body for medical institution.kvo and bolus functionCompatible Syringe: Any standard syringe with 10ml20ml(30ml) and 50ml(60ml)Accuracy: ±2% ( Any manufacturers of syringes, right after calibration )Delivery Rate Range:50ml(60ml)0.1ml/h∼1800.0ml/h (0.1ml/h step)20ml(30ml)0.1ml/h∼800.0ml/h (0.1ml/h step)10ml0.1ml/h∼400.0ml/h (0.1ml/h step)Time Mode Range:Volume0.1∼999.9ml (0.1ml step)TIME1∼1999min (1min step)Body Weight Mode Range: Volume0.1∼999.9ml(0.1ml step)DRUG MASS0.1∼999.9mg(0.1mg step)DOSE0.01∼99.99ug/kg/min(0.01ug/kg/min step)WEIGHT0.1∼300kg(0.1kg the least step)Volume Limit Range: 0∼1999.9ml (0.1 ml step)Total Volume Range: 0.1∼1999.9ml (0.1 ml step)Rapid injection: 50ml(60ml)1800.0ml/h, 20ml(30ml)800.0ml/h, 10ml400.0ml/hKVO Rate: 1ml/hAlarms: Near empty, Syringe empty, Volume complete(a volume limit has been set ), Occlusion, Syringe loose, Operation error, Low battery and other device failures.Power Supply: AC power supply: AC 100 to 240V±10%,50/60HzInternal LI Battery: 11.1V, 2000mAh. Approximmately 8 hours of continuous operation on a new and fully  charged battery running at 5ml/h.Power Consumption: ≤25VASafety level: Class, Type BFDimensions: 230mm(L)×150mm(W)×125mm(H)Net Weight: Approximately. 2.0kgOperating Conditions: Ambient temperature: 5 to 40Relative humidity: 20 to 90%Storage Condition: Ambient temperature: -10 to 55Relative humidity: 10 to 90%Accessories: AC power line, Operational manual

smart syringe pumps 8 channels

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.