Online UPS/High frequency UPS 1KVA-3KVA
Shenzhen Sunray Power Co., Ltd. [China]
High frequency online UPS Double conversion and IGBT technology Advanced battery management Crest factor1:3 Wide input range
High frequency online UPS
Key Features
True on-line double conversion technology with advanced microprocessor control Wide input voltage range Zero transfer time Protection against all type of power problems Self test while start of the UPS Site wiring fault warning On-battery power-on function Smart RS232 communication interface Intelligent slot available Sealed lead-acid, maintenance free battery Technical SpecificationsProduct Series | CASTLE | |||
Model | BS1K | BS2K | BS3K | |
Rated Power | VA/W | 1kVA / 0.7kW | 2kVA / 1.4kW | 3kVA / 2.1kW |
Input | Nominal Voltage | 110V/220VAC | ||
Voltage Range | 60V~136V/115 ~ 300VAC | |||
Frequency Range | 46~54Hz(default), user adjustable within 40~60Hz | |||
Power Factor | 0.97 | |||
Connection | IEC320-10A inlet | IEC320-16A inlet | ||
Output | Voltage | 110V/220VAC ± 2% | ||
Frequency | 46~54Hz or 50Hz ± 0.2Hz (Line mode)50Hz ± 0.2Hz ( Battery mode) | |||
Waveform | Sine Wave | |||
Distortion | 3% | 4% | ||
Overload Capability | 108%~150% for 30 sec., ³150% for 300 ms | |||
Current Crest Ratio | 3:1 | |||
Connections | IEC320 * 4 | IEC320 * 6 | IEC320 * 3 andTerminal Block | |
Battery | Type | Sealed, Maintenance free, Lead-Acid | ||
Quantity | 3 pieces | 8 pieces | ||
Back-up Time (Full load) | 5 min | 9 min | 5 min | |
Recharge Time | 5 hrs to 90% of capacity after full load discharge | |||
Bypass | Automatic Transfer | on overload and UPS failure | ||
Before UPS Power-on | Default NO, user adjustable to YES | |||
Voltage Range | 80~264VAC (Default), user adjustable within 80~286VAC | |||
Transfer Time | 0 ms; less than 4 ms from inverter to bypass and vice versa | |||
LED Indicators | Status | Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault | ||
Audible Alarm | Bypass, On battery mode, Battery low, Overload, Fault | |||
Acoustic Noise | At 1 meter distance | 45 dBA | 50 dBA | |
Communications | DB-9 Port | RS-232 Serial Interface | ||
Intelligent Slot | Options: WebPower, AS400 Card or WinPower CMC | |||
Network Surge Protection | RJ45 I/O port available for network or Fax/Modem | |||
Environmental | Operating Temperature | 0 ~ 40°C | ||
Operating Humidity | 20 ~ 90% non-condensing | |||
Weight | Net (Kg) | 13 | 31.5 | 32 |
Dimensions | W x D x H (mm) | 145 x 400 x 220 | 192 x 460 x 348 |
Online UPS/High frequency UPS 1KVA-3KVA