CSA Approved ,Flare x Male,Brass Gas Ball Valve
1) Brass Gas Ball Valve MIPxFLARE,CSA approvel 2) Size: 1/2"MIPx3/8"FL 1/2"MIPx1/2"FL with CSA 1/2G &5G
CSA Approved Brass Gas Ball Valve MIPxFLARE, CSA Approval
MODEL NO: 1023
Description:
1) MIP x FLARE - Lever Handle2) 600 PSI/41.4 Bar Non-Shock Cold Working Pressure 3) 1/2 PSI for indoor appliance connections per ANSI Z21.15 & CGA 9.1 4) 5 PSI for indoor shutoff per CGA 91-002 and ASME B16.445) Size - 1/2"MIP x 3/8"FLARE , 1/2"MIP x 1/2"FLARE
6) Two-piece body - double o-ring packing - PTFE seats - aluminum handle
CSA Approved ,Flare x Male,Brass Gas Ball Valve
Verified Information This information is Verified by Bureau Veritas and validity period is 2012/09/11 --- 2013/09/11 All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >> Production Capacity:Brass Valves, Bronze Valves, Brass OEM Products, Bronze OEM Products | 9,039,156 Sets Per Year | 6,889,152 Sets |
North America | confidential | 65.96 |
Southeast Asia | confidential | 0.92 |
Oceania | confidential | 7.39 |
Western Europe | confidential | 25.73 |
Milling machine | B800, XQ6225 | 3 | 8.0 | Acceptable |
Engine lathe | CA6150A, CA6140 | 4 | 8.0 | Acceptable |
Wire electric discharge machine | DK7740 | 3 | 8.0 | Acceptable |
Machining center | VMC650 | 2 | 3.0 | Acceptable |
Shot blasting machine | Q3210F | 6 | 5.0 | Acceptable |
Bench drill | Z5140, Z512-2 | 16 | 8.0 | Acceptable |
Vertical drilling machine | Z5140A | 4 | 8.0 | Acceptable |
Multifunction machine | YC-110HV | 20 | 8.0 | Acceptable |
CNC machine | CNC360, CJK0640, KC0630 | 30 | 4.0 | Acceptable |
Press | JC23-63, J31-125, J31-200, J23-25, JD31-400 | 16 | 6.0 | Acceptable |
Automatic equipment machine | HS-16RM | 2 | 1.0 | Acceptable |
Torsion machine | BFSR-80 | 6 | 3.0 | Acceptable |
Spectrum analyzer | THERMO3460 | 1 | 6.0 | Acceptable |
Brinell's machine | BDH-3000 | 1 | 6.0 | Acceptable |
Microscope | DIG300 | 2 | 6.0 | Acceptable |
Surface roughness tester | SRM | 1 | 5.0 | Acceptable |
Universal testing machine | CMT5105 | 1 | 4.0 | Acceptable |
Image tester | JVL250 | 1 | 5.0 | Acceptable |
Electrolytic thickness gauge | GALVANO300 | 1 | 1.0 | Acceptable |
Metallographic polishing machine | P-1A | 1 | 1.0 | Acceptable |
Salt spray test machine | AKD-60 | 1 | 0.5 | Acceptable |
ISO9001:2008 | CQC, CNAS | 00112Q27250R0M/3302 | Design Production and Service of Export 4-100mm Ball Valves, 15-50mm Check Valves, Y-Strainer, 15-100mm Gate Valve and Brass & Bronze Assemblies | 2012/07/24 --- 2015/07/23 | |
FM | FM Approvals | 0003046676 | Quick Opening Valves & Q104LF, Q104LF-LH, Q105LF/ Brass Ball Valves & Size 1/4 Through 2 Inch NPS | 2012/07/26 --- 2049/12/31 |
EN331 Test Report | BSI | Ball Valve & Q104FEU, Q134, 1028 | 2011/09/29 |