Ultra high performance flexible welding lead, double insulated Better flame retardant properties Excellent flexibility to l
Cable Structure
Generally conforms to, Based on CENELEC HD 22-6 31, VDE 0282 ,IEC 245-6, BS 6899 , IS 6830/84
Conductor:High conductivity, bare annealed copper flexible conductor, EC copper class 5 and class 6 Generally conforms to IEC 60228, DIN VDE 0281
Insulation:Double Insulated flexible Nitrile rubber (NBR) insulated
Colour code:Orange & Black Jacket*Any other Color on specific request can also be supplied
Technical Data
Fixed installation: | -30°c to max.+90°C |
Nominal voltage: | 600 V |
Test voltage: | 3000 V |
Insulation resistance: | Min. 10 MΩ x km |
Min. bending radius: | 6 x cable diameter |
Flame propagation: | Flame retardant test as per IEC 60332-1 |
Application
NBR/NBRDesigned for the secondary (high current) connection to automatic or hand – held metal arc welding electrodes. It is suitable for flexible use under rugged conditions, on assembly lines and conveyor systems, in machine tool and automatically operated line and spot welding machines.Standard length cable packing:Coils 100, 200,300 and 500 m. in wooden reels
Cable features
Ultra high performance flexible welding lead, double insulated Better flame retardant properties Excellent flexibility to last longer in flex applicationsBased on CENELEC HD 22-6 31, VDE 0282, IEC 245-6, IS 473, BS 638-4 Outstanding toughness & durability High resistance to cuts, tears & abrasion Resistance to oil, solvents and chemicals Excellent ozone and weather resistantHeat and Oil Resistant and Flame Retardant Welding cables